XPQ Static Var Generator - 400V/690V Reactive Power Compensator from China Suppliers & Factory for Improved Power Quality
Features
1. Compensation Ability
The system can adjust the reactive power output based on site conditions to prevent overcompensation or undercompensation, ensuring a power factor of 0.99.
2. Fast Response
Fully digital control. The harmonic current detection utilizes an efficient TTA algorithm based on time domain exchange. This enables quick and accurate calculation of the instantaneous value of reactive current, leading to a significant improvement in compensation response time and achieving a full response within 10ms.
3. High-End Quality of Core Components
German original IGBT module, three-level topology. The control system is comprised of the American TIDSP control chip, as well as ALTERA and CYCLONE 3 series FPGA chips, making it a powerful three-core system. Additionally, TI's double-ended high-speed input 12-bit A/D data conversion chip enhances the accuracy and reliability of signal sampling.
4. Efficient Heat Dissipation
The layered heat dissipation design allows for independent air ducts, leading to improved heat dissipation performance and effectively preventing dust and other pollutants from affecting the control system.
5. Independent Fan, Detachable
The fans can be easily disassembled and reassembled independently, enhancing heat dissipation reliability.
6. Modular Design
Various capacity modules can be installed in any combination to improve the reliability and maintainability of the whole machine.
7. Human-Machine Interface
Single module can be equipped with a 5-inch LCD touchscreen, and multiple modules can have an external 7-inch LCD touchscreen. It supports real-time monitoring of operating data and online change of control parameters. It is simple to operate and can be equipped with an optional mobile phone APP for remote control.
Basic Parameters
| Compensation capacity / Kvar | 25 | 30 | 50 | 75 | 100 | 100 | |
| AC input | Rated voltage | 400V (±15%) | 690V (±15%) | ||||
| Working frequency | (50±10%) Hz | ||||||
| Wiring method | 3-phase 4-wire or 3-phase 3-wire | ||||||
| Technical Parameter | Filtering capability |
≥97%; Excess capacity is compensated at maximum capacity |
|||||
| Power consumption | ≤3% of rated capacity | ||||||
| Module expansion capability | Up to 10 function modules | ||||||
| Switching frequency | 20kHz | ||||||
| Circuit topology | Three-level | ||||||
| Compensation range | Inductive reactive power and capacitive reactive power can be continuously compensated | ||||||
| Filter level setting | Each harmonic can be individually set, and the ability to selectively eliminate specific harmonics (enhanced SVG) and ordinary SVG without filtering | ||||||
| Compensation range | Inductive reactive power, capacitive reactive power can be continuously compensated | ||||||
| Compensation range | The maximum inrush current | Not more than rated current | |||||
| Response time | 100μs/10ms | ||||||
| Protection function | Grid overvoltage, undervoltage, overcurrent, bus overvoltage, overheating and current limiting protection, etc., with a delay of 5μs | ||||||
| Display function |
|
||||||
| Communication Interface | RS232, RS485; WIFI and GPRS optional | ||||||
| Performance | Noise | <65dB | |||||
| Target power factor | -0.99 ~ 0.99 adjustable | ||||||
| Cooling method | Forced air cooling | ||||||
| Ambient temperature | -10℃ ~ +40℃ | ||||||
| Storage temperature | -20℃ ~ +60℃ | ||||||
| Humidity Maximum | Max 95%RH (non-condensing) | ||||||
| Altitude | Altitude ≤1500m, according to GB/T3859.2, the capacity decreases by 1% for every 100M increase | ||||||
| Protection grade | IP20 (other protection grades can be customized) | ||||||
| Mechanical characteristic | Color |
Acrylic black; other colors can be customized on request. |
|||||
| Operating characteristics |
Operating safely and reliably 24/7 without disrupting the normal operation of other system equipment. The module has protection measures such as overhumidity, overvoltage, undervoltage, overload and overcurrent, short circuit and system self-diagnosis function. If a fault such as a short circuit occurs inside the module, it can protect itself without affecting the external power system. If the compensation energy required by the load is greater than the rated compensation energy, it can be output according to the main body capacity and continue to compensate without overloading or causing equipment damage and exiting operation. |
||||||
Model Specifications
Dimensions
Drawer type
| Model No. | Dimensions (mm) | |||||||
|---|---|---|---|---|---|---|---|---|
| W | H | D | w | d | h | Set screw | Net weight(kg) | |
| XPQ - SG - 4L - 030 | 484 | 200 | 640 | 465 | 158 | 610 | M6 | 34 |
| XPQ - SG - 4L - 050 | ||||||||
| XPQ - SG/MG - 4L - 075 | ||||||||
| XPQ - SG/MG - 4L - 100 | 544 | 250 | 646 | 525 | 180 | 610 | 47 | |
| XPQ - MG - 4L - 030 | 392 | 200 | 555 | 373 | 158 | 530 | 29 | |
| XPQ - MG - 4L - 050 | 392 | 200 | 555 | 373 | 158 | 530 | 29 | |
Wall-mounted type
| Model No. | Dimensions (mm) | |||||||
|---|---|---|---|---|---|---|---|---|
| W | H | D | w | d | h | Set screw | Net weight(kg) | |
| XPQ - SG - 4L - 030 | 440 | 657 | 212 | 375 | 633 | / | M8 | 35 |
| XPQ - SG - 4L - 050 | ||||||||
| XPQ - SG/MG - 4L - 075 | ||||||||
| XPQ - SG/MG - 4L - 100 | 500 | 657 | 262 | 375 | 633 | / | 48 | |
| XPQ - MG - 4L - 030 | 348 | 577 | 208 | 275 | 553 | / | 30 | |
| XPQ - MG - 4L - 050 | / | 30 | ||||||
Drawer type (lightweight)
| Model No. | Dimensions (mm) | |||||||
|---|---|---|---|---|---|---|---|---|
| W | H | D | w | d | h | Set screw | Net weight(kg) | |
| XPQ - CG - 4L - 030 | 88 | 520 | 420 | / | 507.6 | / | M6 | 15 |
| XPQ - CG - 4L - 050 | ||||||||
Wall-mounted (lightweight)
| Model No. | Dimensions (mm) | |||||||
|---|---|---|---|---|---|---|---|---|
| W | H | D | w | d | h | Set screw | Net weight(kg) | |
| XPQ - CG - 4L - 030 | 460 | 473 | 101.2 | 350 | 454 | / | M8 | 15 |
| XPQ - CG - 4L - 050 | ||||||||
Frequently Asked Questions
QWhat is the target power factor achieved by this SVG system?
The system dynamically adjusts reactive power output based on real-time site conditions to eliminate overcompensation or undercompensation, providing an adjustable target power factor range from -0.99 to 0.99.
QHow fast does the system respond to reactive power fluctuations?
Featuring fully digital control and the TTA time-domain exchange algorithm, the device calculates instantaneous reactive current rapidly, reaching a response time of 100μs and completing full compensation within 10ms.
QWhat are the key hardware components utilized in the unit?
The unit integrates original German IGBT modules with a three-level circuit topology, a three-core control architecture (American TI DSP with ALTERA/CYCLONE 3 FPGA), and TI dual-input high-speed 12-bit A/D conversion chips.
QCan multiple modules be combined for higher capacity?
Yes, the modular design supports flexible combinations of multiple capacities, allowing expansion of up to 10 function modules in parallel to improve scalability and system maintainability.
QWhat display and remote control options are available?
Individual modules can feature a 5-inch LCD touchscreen, while multi-module systems can utilize an external 7-inch LCD touchscreen. RS232, RS485 communication protocols are supported, with optional WIFI, GPRS, and a mobile phone APP for remote monitoring.
QHow does the module protect itself during faults or excessive load?
It includes multi-layer protections (grid overvoltage/undervoltage, overcurrent, overheating, short circuit, 5μs delay protection) and self-diagnostics. If the load demand exceeds rated capacity, the unit outputs at its maximum continuous limit without overloading or shutting down.