Introducing the XFC500 General-Purpose Series VFD, a high-performance variable frequency drive designed for precise control of asynchronous motors. Leveraging a cutting-edge DSP control platform, this VFD excels in implementing a sensorless vector control algorithm, making it ideal for fan and water pump applications, **Key Specifications:**, - **Input Voltage:** 3-phase 380V ~ 480V, 50/60Hz, - **Output Voltage:** Matches the input voltage, - **Power Range:** 1.5kW ~ 450kW, **Features:**, - **Built-in DC Reactors:** Models rated at 132kW and above come equipped with built-in DC reactors, enhancing functionality and efficiency, - **Expandable Applications:** The XFC500 supports flexible application function expansions, with options for IO expansion cards and PLC expansion cards, - **Diverse Communication Interfaces:** The expansion interface allows easy connection of various communication expansion cards, including CANopen, Profibus, and EtherCAT, - **User-Friendly Design:** A detachable LED operation keyboard ensures seamless operation and management, - **Supported Configurations:** Both common DC bus and DC power supplies are supported, As a top choice among China suppliers and factories, the XFC500 Series VFD embodies reliability and advanced technology, tailored for diverse industrial applications. Experience unparalleled performance and superior motor control with our innovative drive solutions

    Features

    Superior motor drive and protection performance
    • High-precision motor parameter self-learning function
    • High-performance open-loop vector control
    • Stable overvoltage, over-current stall control, reducing the number of failures
    • Efficient instantaneous power failure protection function
    High reliability design
    • Electromechanical collaborative design to ensure the close cooperation between electronic components and structural parts
    • Accurate thermal simulation design ensures the best heat dissipation efficiency of the product
    • Excellent EMC(Electromagnetic Compatibility)design to reduce harmonic interference
    • More than 100 rigorous system tests to ensure the high performance and high quality of products
    • The temperature rise verification of the whole machine ensures the safe operation of the product
    Flexible application
    • Multiple application function expansion enhances the applicability of the product
    • Rich communication expansion to meet the networking control requirements of different fieldbuses
    • High-performance LED keyboard, shuttle knob, clear display and easy operation
    • Support common DC bus and DC power supply
    • EMC safety capacitor grounding (optional)
    • Various installation methods - please refer to the product installation diagram for details

    Basic Parameters

    Item Parameter
    Power supply Rated supply voltage 3 phase 380V ~ 480V
    Allowed voltage fluctuations -15% ~ +10%
    Rated supply frequency 50/60Hz
    Allowed Frequency Fluctuations ±5%
    Output Max output voltage Three-phase 380V ~ 480V (Go after the input voltage)
    Max Output frequency 500Hz
    Carrier Frequency 0.5 ~ 16kHz (automatic adjustment according to the temperature, and the adjustment range differs for different models)
    Overload capacity

    Type G: 150% rated current 60s; 180% rated current 3s.

    Type P: 120% rated current 60s; 150% rated current 3s.

    Basic Functions Frequency setting resolution

    Digital setting: 0.01Hz

    Analog setting: max frequency × 0.025%

    Control Mode

    Open Loop Vector Control (SVC)

    V/F Control

    Pull-in torque 0.3Hz/150% (SVC)
    Speed range 1 : 200 (SVC)
    Speed Stabilizing accuracy ±0.5% (SVC)
    Torque boost

    Automatic torque boost

    Manual torque increase 0.1% ~ 30.0%

    V/F Curve

    Three ways: linear type; multi-point type; N-th power V/F curve (n=1.2, 1.4, 1.6, 1.8, 2)

    Acceleration and deceleration curve

    Linear or S-curve acceleration and deceleration;

    Four kinds of acceleration and deceleration time.

    Adjustable range 0.0 ~ 6500.0S

    DC braking

    Frequency of DC braking: 0.00Hz ~ max frequency

    Braking time: 0.0s ~ 36.0s

    Braking action current value: 0.0% ~ 100.0%

    Jogging control

    Jogging frequency range: 0.00Hz ~ 50.00Hz

    Jog acceleration-deceleration time: 0.0s ~ 6500.0s

    Simple PLC, multi-stage speed operation Up to 16-stage speed operation via built-in PLC or control terminal
    Built-in PID Implementing closed-loop control in process control applications
    Overvoltage and overcurrent stall control Automatically limit current and voltage during operation to prevent fault shutdown due to frequent over-current and over-voltage
    Fast current limiting function Reduce overcurrent fault shutdown to ensure the normal operation of the frequency converter
    Control interface Digital input 5 multi-function digital inputs (one of which supports max 100kHz pulse input function)
    Analog input 2 analog inputs (both supporting 0 ~ 10V or 0 ~ 20mA analog input, switch voltage or current input via jumper)
    Digital output 2 open-collector digital outputs (one of which supports max 100KHz square wave output)
    Analog output 1 analog output (supporting 0 ~ 10V or 0 ~ 20mA analog output, switch voltage or current input via jumper)
    Relay output 1-channel relay output, including 1 normally open contact, 1 normally closed contact
    Standard communication interface 1 channel RS485 communication interface
    Expansion interface Function expansion interface Connectable to IO expansion card, PLC programmable expansion card, etc.
    Operation panel LED digital display 5-digit display of parameters and settings
    Indicator light 4 status indications, 3 unit indications
    Button’s Function 5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00
    Shuttle Knob Add, minus and confirm
    Parameter copy Fast upload and download parameters
    Protective function Basic protection Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions
    Environment Operation condition Indoor, no conductive dust and oil, etc.
    Operating ambient temperature -10°C ~ +40°C (40°C ~ 50°C, derate 1.5% for every 1°C increase in temperature)
    Humidity Less than 95% RH, no condensation
    Operating altitude No derating below 1000m, derate by 1% for every 100m elevation above 1000m
    Ambient temperature for Storage -20℃ ~ +60℃
    Vibration Less than 5.9m/s² (0.6g)
    Installation method Wall-mounted or flush-mounted installation in the cabinet (Need to choose the appropriate installation accessories)
    IP degree of protection IP20

    Model Specifications

    XFC500 VFD Model definition3e3
    Model No. Motor power / kW Rated input Capacity / kVA Rated input current / A Rated output current / A
    XFC500-3P4-1k50G-BEN-20 1.5G 3.2 4.8 4
    XFC500-3P4-2k20G-BEN-20 2.2G 4.5 6.8 5.6
    XFC500-3P4-4k00G-BEN-20 4G 7.9 12 9.7
    XFC500-3P4-5K50G/7K50P-BEN-20 5.5G 11 16 13
    7.5P 14 21 17
    XFC500-3P4-7K50G/11k0P-BEN-20 7.5G 14 21 17
    11P 20 30 25
    XFC500-3P4-11K0G/15K0P-BEN-20 11G 20 30 25
    15P 27 41 33
    XFC500-3P4-15K0G/18K5P-BEN-20 15G 27 41 33
    18.5P 33 50 40
    XFC500-3P4-18K5G/22K0P-BEN-20 18.5G 33 50 40
    22P 38 57 45
    XFC500-3P4-22K0G/30K0P-BEN-20 22G 38 57 45
    30P 51 77 61
    XFC500-3P4-30K0G/37K0P-NEN-20 30G 51 77 61
    37P 62 94 74
    XFC500-3P4-37K0G/45K0P-NEN-20 37G 62 94 74
    45P 75 114 90
    XFC500-3P4-45K0G/55K0P-NEN-20 45G 75 114 90
    55P 91 138 109
    XFC500-3P4-55K0G/75K0P-NEN-20 55G 91 138 109
    75P 123 187 147
    XFC500-3P4-75K0G/90K0P-NEN-20 75G 123 187 147
    90P 147 223 176
    XFC500-3P4-90K0G/110KP-NEN-20 90G 147 223 176
    110P 179 271 211
    XFC500-3P4-110KG/132KP-NEN-20 110G 179 271 211
    132P 200 303 253
    XFC500-3P4-132KG/160KP-NEN-20 132G 167 253 253
    160P 201 306 303
    XFC500-3P4-160KG/185KP-NEN-20 160G 201 306 303
    185P 233 353 350
    XFC500-3P4-185KG/200KP-NEN-20 185G 233 353 350
    200P 250 380 378
    XFC500-3P4-200KG/220KP-NEN-20 200G 250 380 378
    220P 275 418 416
    XFC500-3P4-220KG/250KP-NEN-20 220G 275 418 416
    250P 312 474 467
    XFC500-3P4-250KG/280KP-NEN-20 250G 312 474 467
    280P 350 531 522
    XFC500-3P4-280KG/315KP-NEN-20 280G 350 531 522
    315P 393 597 588
    XFC500-3P4-315KG/355KP-NEN-20 315G 393 597 588
    355P 441 669 659
    XFC500-3P4-355KG/400KP-NEN-20 355G 441 669 659
    400P 489 743 732
    XFC500-3P4-400KG/450KP-NEN-20 400G 489 743 732
    450P 550 835 822
    XFC500-3P4-450KG-NEN-20 450G 550 835 822

    Dimensions

    XFC500 Low-voltage VFD (1)7nv
    Model W H D w h h1 d t Fixing screws Net Weight

    XFC500-3P4-1K50G-BEN-20

    XFC500-3P4-2K20G-BEN-20

    XFC500-3P4-4K00G-BEN-20

    110 228 177 75 219 200 172 1.5 M5 2.5kg / 5.5lb
    XFC500 Low-voltage VFD (2)d5s
    Model W H D w h h1 d t Fixing screws Net Weight

    XFC500-3P4-5K50G-BEN-20

    XFC500-3P4-7K50G-BEN-20

    140 268 185 100 259 240 180 1.5 M5 3.2kg / 7.1lb

    XFC500-3P4-11K0G-BEN-20

    XFC500-3P4-15K0G-BEN-20

    170 318 225 125 309 290 220 5kg / 11lb

    XFC500-3P4-18K5G-BEN-20

    XFC500-3P4-22K0G-BEN-20

    190 348 245 150 339 320 240 6kg / 13.2lb
    XFC500 Low-voltage VFD (3)15h
    Model W H D w h h1 d t Fixing screws Net Weight

    XFC500-3P4-30K0G-BEN-20

    XFC500-3P4-37K0G-BEN-20

    260 500 260 200 478 450 255 1.5 M6 17kg / 37.5lb

    XFC500-3P4-45K0G-BEN-20

    XFC500-3P4-55K0G-BEN-20

    295 570 307 200 550 520 302 2 M8 22kg / 48.5lb

    XFC500-3P4-75K0G-BEN-20

    XFC500-3P4-90K0G-BEN-20

    XFC500-3P4-110KG-BEN-20

    350 661 350 250 634 611 345 2 M10 48kg / 105.8lb

    XFC500-3P4-132KG-BEN-20

    XFC500-3P4-160KG-BEN-20

    450 850 355 300 824 800 350 2 M10 91kg / 200.7lb
    XFC500 Low-voltage VFD (4)pu8
    Model W H D w h h1 h2 d W1 Fixing screws Net Weight

    XFC500-3P4-185KG-BEN-20

    XFC500-3P4-200KG-BEN-20

    XFC500-3P4-220KG-BEN-20

    XFC500-3P4-250KG-BEN-20

    XFC500-3P4-280KG-BEN-20

    340 1218 560 200 1150 1180 53 545 400 M12 210kg / 463.1lb

    XFC500-3P4-315KG-BEN-20

    XFC500-3P4-355KG-BEN-20

    XFC500-3P4-400KG-BEN-20

    XFC500-3P4-450KG-BEN-20

    340 1445 560 200 1375 1410 56 545 400 245kg / 540.2lb

    Accessories (Optional)

    Image Expansion type Model No. Function Install port Install quantity
    XFC500 Low-voltage VFD detail (1)94n IO expansion card XFC5-IOC-00 5 digital inputs, 1 analog input, 1 relay output, 1 open collector output, and 1 analog output can be added, with CAN interface. X630 1
    XFC500 Low-voltage VFD detail (2)x01 Programmable expansion card XFC5-PLC-00 Connect with the VFD to form a PLC+VFD combination, compatible with Mitsubishi PLC programming environment. The card has 5 digital inputs, 1 analog input, 2 relay outputs, 1 analog output, and RS485 interface. X630 1
    XFC500 Low-voltage VFD detail (3)cax Profibus-DP expansion card XFC5-PFB-00 It has Profibus-DP communication function, fully supports Profibus-DP protocol, and supports baud rate adaptive function, which allows the VFD to be connected to the Profibus communication network to realize real-time reading of all function codes of the VFD and realize field bus control. X630 1
    XFC500 Low-voltage VFD detail (4)19n CANopen expansion card XFC5-CAN-00 The VFD can be connected to the high-speed CAN communication network to realize field bus control. The CANopen expansion card supports Heartbeat protocol, NMT messages, SDO messages, 3 TPDOs, 3 RPDOs, and emergency objects. X630 1
    XFC500 Low-voltage VFD detail (5)gt1 Ethercat expansion card XFC5-ECT-00 With Ethercat communication function and fully supports the Ethercat protocol, which allows the VFD to be connected to the Ethercat communication network to realize real-time reading of the VFD function code and field bus control. X630 1

    Frequently Asked Questions

    What control modes are supported by the XFC500 VFD?
    The XFC500 supports two main control modes: Open Loop Vector Control (SVC) and V/F Control, offering high-performance motor drive capabilities.
    What is the overload capacity of the XFC500 VFD?
    It features dual ratings:
    • Type G (Heavy duty): 150% rated current for 60 seconds; 180% rated current for 3 seconds.
    • Type P (Normal duty): 120% rated current for 60 seconds; 150% rated current for 3 seconds.
    What optional expansion cards are available for the XFC500?
    The XFC500 supports various optional expansion cards to enhance application flexibility, including:
    • IO Expansion Card (XFC5-IOC-00)
    • Programmable PLC Expansion Card (XFC5-PLC-00)
    • Profibus-DP Expansion Card (XFC5-PFB-00)
    • CANopen Expansion Card (XFC5-CAN-00)
    • Ethercat Expansion Card (XFC5-ECT-00)
    What are the environmental requirements for operating the XFC500 VFD?
    The VFD should be installed indoors in an environment free of conductive dust, oil, and condensation. The operating ambient temperature ranges from -10°C to +40°C (derating by 1.5% per 1°C up to 50°C). It operates up to 1000m altitude without derating.
    Does the XFC500 operation panel support parameter copying?
    Yes, the operation panel supports parameter copy functionality, allowing for fast upload and download of parameters to simplify setup and configuration across multiple units.
    What built-in protection functions does the XFC500 have?
    The XFC500 includes comprehensive basic protections: input/output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, and fast current limiting to prevent fault shutdowns.