High-Performance XFC550 VFD for Motor Control, 3 Phase 380V, from China Suppliers & Factory
Features
The system is equipped with four sets of motor control parameters to accommodate four motors with varying process requirements and power segments. This addresses the issue of VFD backup and replacement at the project site. Parameters can be preset for each group, allowing seamless switching through the DI terminal without additional adjustments.
Users have the flexibility to choose I/O expansion cards based on their specific digital and analog function requirements, offering convenience for design and debugging.
Supports simultaneous application of two built-in expansion cards. One channel is for function and communication extensions (such as IO, PLC programmable, etc.), while the other channel is for an encoder expansion card (compatible with differential, OC interface encoder, and resolver expansion card, etc.).
High-performance over-current and over-voltage stall control effectively meets varied load requirements of different mechanical characteristics, allowing the motor to adapt to both hard and soft mechanical characteristics.
Basic Parameters
| Item | Parameter | |
|---|---|---|
| Power supply | Rated supply voltage | 3 phase 380V ~ 480V |
| Allowed voltage fluctuations | -15%~+10% | |
| Rated supply frequency | 50/60Hz | |
| Allowed Frequency Fluctuations | ±5% | |
| Output | Max output voltage | Three-phase 380V~480V (Go after the input voltage) |
| Max Output frequency | 500Hz | |
| Carrier Frequency | 0.5 ~ 16kHz (automatic adjustment according to the temperature, and the adjustment range differs for different models) | |
| Overload capacity | 150% rated current 60s; 180% rated current 3s. | |
| Basic Functions | Frequency setting resolution | Digital setting: 0.01Hz Analog setting: max frequency * 0.025% |
| Control Mode | Open Loop Vector Control (SVC) Closed Loop Vector Control (FOC) V/f Control |
|
| Pull-in torque | 0.3Hz/150% (SVC) 0 Hz/180% (FOC) |
|
| Speed range | 1 : 200 (SVC) 1 : 1000 (FOC) |
|
| Speed Stabilizing accuracy | ±0.5% (SVC) ±0.02% (FOC) |
|
| Torque Control Precision | ±5% (FOC) | |
| Torque boost | Automatic torque boost Manual torque increase 0.1% ~ 30.0% |
|
| V/F Curve | Three ways: linear type; multi-point type; N-th power V/F curve (n=1.2, 1.4, 1.6, 1.8, 2) | |
| Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration; 4 kinds of acceleration and deceleration time. Adjustable range 0.0~6500.0S | |
| DC braking | Frequency of DC braking: 0.00Hz ~ max frequency Braking time: 0.0s ~ 36.0s Braking action current value: 0.0% ~ 100.0% |
|
| Jogging control | Jogging frequency range: 0.00Hz ~ 50.00Hz Jog acceleration-deceleration time: 0.0s ~ 6500.0s |
|
| Simple PLC, multi-stage speed operation | Up to 16-stage speed operation via built-in PLC or control terminal | |
| Built-in PID | Implementing closed-loop control in process control applications | |
| Overvoltage and overcurrent stall control | Automatically limit current and voltage during operation to prevent fault shutdown due to frequent over-current and over-voltage | |
| Fast current limiting function | Reduce overcurrent fault shutdown to ensure the normal operation of the VFD | |
| Control interface | Digital input | 5 multi-function digital inputs. One of which supports max 100kHz pulse input function |
| Analog input | 2 analog inputs. Both supporting 0 ~ 10V or 0 ~ 20mA analog input, switch voltage or current input via jumper | |
| Digital output | 2 open-collector digital outputs. One of which supports max 100KHz square wave output | |
| Analog output | 1 analog output. Supporting 0 ~ 10V or 0 ~ 20mA analog output, switch voltage or current input via jumper | |
| Relay output | 1-channel relay output, including 1 normally open contact, 1 normally closed contact | |
| Standard communication interface | 1 channel RS485 communication interface | |
| Expansion interface | Function expansion interface | Connectable to IO expansion card, PLC programmable expansion card, etc. |
| Operation panel | LED digital display | 5-digit display of parameters and settings |
| Indicator light | 4 status indications, 3 unit indications | |
| Button’s Function | 5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00 | |
| Shuttle Knob | Add, minus and confirm | |
| Parameter copy | Fast upload and download parameters | |
| Protective function | Basic protection | Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions |
| Environment | Operation condition | Indoor, no conductive dust and oil, etc. |
| Operating ambient temperature | -10°C ~ +40°C (40°C ~ 50°C, derate 1.5% for every 1°C increase in temperature) | |
| Humidity | Less than 95% RH, no condensation | |
| Operating altitude | No derating below 1000m, derate by 1% for every 100m elevation above 1000m | |
| Ambient temperature for Storage | -20℃ ~ +60℃ | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Installation method | Wall-mounted or flush-mounted installation in the cabinet (Need to choose the appropriate installation accessories) | |
| IP degree of protection | IP20 | |
Model Specifications
| Model | Motor power / kW | Rated input Capacity / kVA | Rated input current / A | Rated output current / A |
|---|---|---|---|---|
| XFC550-3P4-1k50G-BEN-20 | 1.5 | 3.2 | 4.8 | 4 |
| XFC550-3P4-2k20G-BEN-20 | 2.2 | 4.5 | 6.8 | 5.6 |
| XFC550-3P4-4k00G-BEN-20 | 4 | 7.9 | 12 | 9.7 |
| XFC550-3P4-5K50G-BEN-20 | 5.5 | 11 | 16 | 13 |
| XFC550-3P4-7K50G-BEN-20 | 7.5 | 14 | 21 | 17 |
| XFC550-3P4-11K0G-BEN-20 | 11 | 20 | 30 | 25 |
| XFC550-3P4-15K0G-BEN-20 | 15 | 27 | 41 | 33 |
| XFC550-3P4-18K5G-BEN-20 | 18.5 | 33 | 50 | 40 |
| XFC550-3P4-22K0G-BEN-20 | 22 | 38 | 57 | 45 |
| XFC550-3P4-30K0G-NEN-20 | 30 | 51 | 77 | 61 |
| XFC550-3P4-37K0G-NEN-20 | 37 | 62 | 94 | 74 |
| XFC550-3P4-45K0G-NEN-20 | 45 | 75 | 114 | 90 |
| XFC550-3P4-55K0G-NEN-20 | 55 | 91 | 138 | 109 |
| XFC550-3P4-75K0G-NEN-20 | 75 | 123 | 187 | 147 |
| XFC550-3P4-90K0G-NEN-20 | 90 | 147 | 223 | 176 |
| XFC550-3P4-110KG-NEN-20 | 110 | 179 | 271 | 211 |
| XFC550-3P4-132KG-NEN-20 | 132 | 167 | 253 | 253 |
| XFC550-3P4-160KG-NEN-20 | 160 | 201 | 306 | 303 |
| XFC550-3P4-185KG-NEN-20 | 185 | 233 | 353 | 350 |
| XFC550-3P4-200KG-NEN-20 | 200 | 250 | 380 | 378 |
| XFC550-3P4-220KG-NEN-20 | 220 | 275 | 418 | 416 |
| XFC550-3P4-250KG-NEN-20 | 250 | 312 | 474 | 467 |
| XFC550-3P4-280KG-NEN-20 | 280 | 350 | 531 | 522 |
| XFC550-3P4-315KG-NEN-20 | 315 | 393 | 597 | 588 |
| XFC550-3P4-355KG-NEN-20 | 355 | 441 | 669 | 659 |
| XFC550-3P4-400KG-NEN-20 | 400 | 489 | 743 | 732 |
| XFC550-3P4-450KG-NEN-20 | 450 | 550 | 835 | 822 |
Dimensions
| Model | W | H | D | w | h | h1 | d | t | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-1K50G-BEN-20 XFC550-3P4-2K20G-BEN-20 |
110 | 228 | 177 | 75 | 219 | 200 | 172 | 1.5 | M5 | 2.5kg / 5.5lb |
| Model | W | H | D | w | h | h1 | d | t | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-4K00G-BEN-20 XFC550-3P4-5K50G-BEN-20 XFC550-3P4-7K50G-BEN-20 |
140 | 268 | 185 | 100 | 259 | 240 | 180 | 1.5 | M5 | 3.2kg / 7.1lb |
| XFC550-3P4-11K0G-BEN-20 XFC550-3P4-15K0G-BEN-20 |
170 | 318 | 225 | 125 | 309 | 290 | 220 | 5kg / 11lb | ||
| XFC550-3P4-18K5G-BEN-20 XFC550-3P4-22K0G-BEN-20 |
190 | 348 | 245 | 150 | 339 | 320 | 240 | 6kg / 13.2lb |
| Model | W | H | D | w | h | h1 | d | t | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-30K0G-NEN-20 XFC550-3P4-37K0G-NEN-20 |
260 | 500 | 260 | 200 | 478 | 450 | 255 | 1.5 | M6 | 17kg / 37.5lb |
| XFC550-3P4-45K0G-NEN-20 XFC550-3P4-55K0G-NEN-20 |
295 | 570 | 307 | 200 | 550 | 520 | 302 | 2 | M8 | 22kg / 48.5lb |
| XFC550-3P4-75K0G-NEN-20 XFC550-3P4-90K0G-NEN-20 XFC550-3P4-110KG-NEN-20 |
350 | 661 | 350 | 250 | 634 | 611 | 345 | 2 | M10 | 48kg / 105.8lb |
| XFC550-3P4-132KG-NEN-20 XFC550-3P4-160KG-NEN-20 |
450 | 850 | 355 | 300 | 824 | 800 | 350 | 2 | M10 | 91kg / 200.7lb |
| Model | W | H | D | w | h | h1 | h2 | d | W1 | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-185KG-NEN-20 XFC550-3P4-200KG-NEN-20 XFC550-3P4-220KG-NEN-20 XFC550-3P4-250KG-NEN-20 XFC550-3P4-280KG-NEN-20 |
340 | 1218 | 560 | 200 | 1150 | 1180 | 53 | 545 | 400 | M12 | 210kg / 463.1lb |
| XFC550-3P4-315KG-NEN-20 XFC550-3P4-355KG-NEN-20 XFC550-3P4-400KG-NEN-20 XFC550-3P4-450KG-NEN-20 |
340 | 1445 | 560 | 200 | 1375 | 1410 | 56 | 545 | 400 | 245kg / 540.2lb |
Accessories (Optional)
| Image | Expansion type | Model No. | Function | Install port | Install quantity |
|---|---|---|---|---|---|
![]() |
IO expansion card |
XFC5-IOC-00 | 5 digital inputs, 1 analog input, 1 relay output, 1 open collector output, and 1 analog output can be added, with CAN interface. | X630 | 1 |
![]() |
Programmable expansion card |
XFC5-PLC-00 | Connect with the VFD to form a PLC+VFD combination, compatible with Mitsubishi PLC programming environment. The card has 5 digital inputs, 1 analog input, 2 relay outputs, 1 analog output, and RS485 interface. | X630 | 1 |
![]() |
Profibus-DP expansion card |
XFC5-PFB-00 | It has Profibus-DP communication function, fully supports Profibus-DP protocol, and supports baud rate adaptive function, which allows the VFD to be connected to the Profibus communication network to realize real-time reading of all function codes of the VFD and realize field bus control. | X630 | 1 |
![]() |
CANopen expansion card |
XFC5-CAN-00 | The VFD can be connected to the high-speed CAN communication network to realize field bus control. The CANopen expansion card supports Heartbeat protocol, NMT messages, SDO messages, 3 TPDOs, 3 RPDOs, and emergency objects. | X630 | 1 |
![]() |
Ethercat expansion card |
XFC5-ECT-00 | With Ethercat communication function and fully supports the Ethercat protocol, which allows the VFD to be connected to the Ethercat communication network to realize real-time reading of the VFD function code and field bus control. | X630 | 1 |
Frequently Asked Questions (FAQ)
The system features four sets of motor control parameters to easily accommodate four motors with different process requirements and power segments, facilitating seamless switching through the DI terminal.
The VFD has an overload capacity of 150% of the rated current for 60 seconds, and 180% of the rated current for 3 seconds.
It supports Open Loop Vector Control (SVC), Closed Loop Vector Control (FOC), and V/f Control modes.
Yes. The XFC550 series supports the simultaneous application of two built-in expansion cards. One is dedicated to function and communication extensions (like IO or PLC programmable cards), and the other is for encoder expansion cards.
The device features an IP20 protection rating. It operates in ambient temperatures from -10°C to +40°C (up to 50°C with 1.5% derating per 1°C increase).
Optional communication cards include Profibus-DP, CANopen, and Ethercat expansion cards, allowing for seamless field bus control integration.