0102030405
High-Performance XFC550 VFD for Motor Control, 3-Phase 380V, from China Suppliers and Factory
Features
● 4 sets of motor control parameters
The system is equipped with four sets of motor control parameters to accommodate four motors with varying process requirements and power segments. This feature addresses the issue of VFD backup and replacement at the project site. The motor parameters can be preset for each group, allowing for seamless switching through the DI terminal during use, without the need for additional adjustments.
● Flexible port configuration
Users have the flexibility to choose I/O expansion cards based on their specific digital and analog function requirements, offering convenience for design and debugging.
● Rich extensions
The XFC550 series inverters support the simultaneous application of two built-in expansion cards, which can be combined to realize a variety of complex system control functions. One channel is for function and communication extensions (such as IO, PLC programmable, etc.), while the other channel is for an encoder expansion card (compatible with differential, OC interface encoder, and resolver expansion card, etc.).
● High-performance stall control
The high-performance over-current and over-voltage stall control can effectively meet the varied load requirements of different mechanical characteristics, allowing the motor to adapt to both hard and soft mechanical characteristics. This makes it suitable for a wide range of engineering equipment applications.
Basic Parameters
| Item | Parameter | |
|---|---|---|
| Power supply | Rated supply voltage | 3 phase 380V ~ 480V |
| Allowed voltage fluctuations | -15%~+10% | |
| Rated supply frequency | 50/60Hz | |
| Allowed Frequency Fluctuations | ±5% | |
| Output | Max output voltage | Three-phase 380V~480V Go after the input voltage |
| Max Output frequency | 500Hz | |
| Carrier Frequency | 0.5 ~ 16kHz (automatic adjustment according to the temperature, and the adjustment range differs for different models ) | |
| Overload capacity | 150% rated current 60s; 180% rated current 3s. |
|
| Basic Functions | Frequency setting resolution | Digital setting: 0.01Hz Analog setting: max frequency * 0.025% |
| Control Mode | Open Loop Vector Control (SVC) Closed Loop Vector Control (FOC) V/f Control |
|
| Pull-in torque | 0.3Hz/150% (SVC) 0 Hz/180% (FOC) |
|
| Speed range | 1 : 200(SVC) 1 : 1000 (FOC) |
|
| Speed Stabilizing accuracy | ±0.5%(SVC) ±0.02% (FOC) |
|
| Torque Control Precision | ±5% (FOC) | |
| Torque boost | Automatic torque boost Manual torque increase 0.1% ~ 30.0% |
|
| V/F Curve | Three ways: linear type; multi-point type; N-th power V/F curve (n=1.2, 1.4, 1.6, 1.8, 2) |
|
| Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration; 4 kinds of acceleration and deceleration time. Adjustable range 0.0~6500.0S |
|
| DC braking | Frequency of DC braking: 0.00Hz ~ max frequency Braking time: 0.0s ~ 36.0s Braking action current value: 0.0% ~ 100.0% |
|
| Jogging control | Jogging frequency range:0.00Hz ~ 50.00Hz Jog acceleration- deceleration time:0.0s ~ 6500.0s |
|
| Simple PLC, multi-stage speed operation | Up to 16-stage speed operation via built-in PLC or control terminal | |
| Built-in PID | Implementing closed-loop control in process control applications | |
| Overvoltage and overcurrent stall control | Automatically limit current and voltage during operation to prevent fault shutdown due to frequent over-current and over-voltage | |
| Fast current limiting function | Reduce overcurrent fault shutdown to ensure the normal operation of theVFD | |
| Control interface | Digital input | 5 multi-function digital inputs. One of which supports max 100kHz pulse input function |
| Analog input | 2 analog inputs. Both supporting 0 ~ 10V or 0 ~ 20mA analog input, switch voltage or current input via jumper |
|
| Digital output | 2 open-collector digital outputs. One of which supports max 100KHz square wave output |
|
| Analog output | 1 analog output. Supporting 0 ~ 10V or 0 ~ 20mA analog output, switch voltage or current output via jumper |
|
| Relay output | 1-channel relay output, including 1 normally open contact, 1 normally closed contact | |
| Standard communication interface | 1 channel RS485 communication interface | |
| Expansion interface | Function expansion interface | Connectable to IO expansion card, PLC programmable expansion card, etc. |
| Operation panel | LED digital display | 5-digit display of parameters and settings |
| Indicator light | 4 status indications, 3 unit indications | |
| Button’s Function | 5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00 | |
| Shuttle Knob | Add, minus and confirm | |
| Parameter copy | Fast upload and download parameters | |
| Protective function | Basic protection | Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions |
| Environment | Operation condition | Indoor, no conductive dust and oil, etc. |
| Operating ambient temperature | -10°C ~ +40°C (40°C ~ 50°C, derate 1.5% for every 1°C increase in temperature | |
| Humidity | Less than 95% RH, no condensation | |
| Operating altitude | No derating below 1000m, derate by 1% for every 100m elevation above 1000m | |
| Ambient temperature for Storage | -20℃ ~ +60℃ | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Installation method | Wall-mounted or flush-mounted installation in the cabinet (Need to choose the appropriate installation accessories) |
|
| IP degree of protection | IP20 | |
Model Specifications
| Model | Motor power / kW | Rated input Capacity / kVA | Rated input current / A | Rated output current / A |
|---|---|---|---|---|
| XFC550-3P4-1k50G-BEN-20 | 1.5 | 3.2 | 4.8 | 4 |
| XFC550-3P4-2k20G-BEN-20 | 2.2 | 4.5 | 6.8 | 5.6 |
| XFC550-3P4-4k00G-BEN-20 | 4 | 7.9 | 12 | 9.7 |
| XFC550-3P4-5K50G-BEN-20 | 5.5 | 11 | 16 | 13 |
| XFC550-3P4-7K50G-BEN-20 | 7.5 | 14 | 21 | 17 |
| XFC550-3P4-11K0G-BEN-20 | 11 | 20 | 30 | 25 |
| XFC550-3P4-15K0G-BEN-20 | 15 | 27 | 41 | 33 |
| XFC550-3P4-18K5G-BEN-20 | 18.5 | 33 | 50 | 40 |
| XFC550-3P4-22K0G-BEN-20 | 22 | 38 | 57 | 45 |
| XFC550-3P4-30K0G-NEN-20 | 30 | 51 | 77 | 61 |
| XFC550-3P4-37K0G-NEN-20 | 37 | 62 | 94 | 74 |
| XFC550-3P4-45K0G-NEN-20 | 45 | 75 | 114 | 90 |
| XFC550-3P4-55K0G-NEN-20 | 55 | 91 | 138 | 109 |
| XFC550-3P4-75K0G-NEN-20 | 75 | 123 | 187 | 147 |
| XFC550-3P4-90K0G-NEN-20 | 90 | 147 | 223 | 176 |
| XFC550-3P4-110KG-NEN-20 | 110 | 179 | 271 | 211 |
| XFC550-3P4-132KG-NEN-20 | 132 | 167 | 253 | 253 |
| XFC550-3P4-160KG-NEN-20 | 160 | 201 | 306 | 303 |
| XFC550-3P4-185KG-NEN-20 | 185 | 233 | 353 | 350 |
| XFC550-3P4-200KG-NEN-20 | 200 | 250 | 380 | 378 |
| XFC550-3P4-220KG-NEN-20 | 220 | 275 | 418 | 416 |
| XFC550-3P4-250KG-NEN-20 | 250 | 312 | 474 | 467 |
| XFC550-3P4-280KG-NEN-20 | 280 | 350 | 531 | 522 |
| XFC550-3P4-315KG-NEN-20 | 315 | 393 | 597 | 588 |
| XFC550-3P4-355KG-NEN-20 | 355 | 441 | 669 | 659 |
| XFC550-3P4-400KG-NEN-20 | 400 | 489 | 743 | 732 |
| XFC550-3P4-450KG-NEN-20 | 450 | 550 | 835 | 822 |
Note: Please contact our sales staff for model selection of 500K and above.
Dimensions
| Model | W | H | D | w | h | h1 | d | t | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-1K50G-BEN-20 | 110 | 228 | 177 | 75 | 219 | 200 | 172 | 1.5 | M5 | 2.5kg / 5.5lb |
| XFC550-3P4-2K20G-BEN-20 |
| Model | W | H | D | w | h | h1 | d | t | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-4K00G-BEN-20 | 140 | 268 | 185 | 100 | 259 | 240 | 180 | 1.5 | M5 | 3.2kg / 7.1lb |
| XFC550-3P4-5K50G-BEN-20 | ||||||||||
| XFC550-3P4-7K50G-BEN-20 | ||||||||||
| XFC550-3P4-11K0G-BEN-20 | 170 | 318 | 225 | 125 | 309 | 290 | 220 | 5kg / 11lb | ||
| XFC550-3P4-15K0G-BEN-20 | ||||||||||
| XFC550-3P4-18K5G-BEN-20 | 190 | 348 | 245 | 150 | 339 | 320 | 240 | 6kg / 13.2lb | ||
| XFC550-3P4-22K0G-BEN-20 |
| Model | W | H | D | w | h | h1 | d | t | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-30K0G-NEN-20 | 260 | 500 | 260 | 200 | 478 | 450 | 255 | 1.5 | M6 | 17kg / 37.5lb |
| XFC550-3P4-37K0G-NEN-20 | ||||||||||
| XFC550-3P4-45K0G-NEN-20 | 295 | 570 | 307 | 200 | 550 | 520 | 302 | 2 | M8 | 22kg / 48.5lb |
| XFC550-3P4-55K0G-NEN-20 | ||||||||||
| XFC550-3P4-75K0G-NEN-20 | 350 | 661 | 350 | 250 | 634 | 611 | 345 | 2 | M10 | 48kg / 105.8lb |
| XFC550-3P4-90K0G-NEN-20 | ||||||||||
| XFC550-3P4-110KG-NEN-20 | ||||||||||
| XFC550-3P4-132KG-NEN-20 | 450 | 850 | 355 | 300 | 824 | 800 | 350 | 2 | M10 | 91kg / 200.7lb |
| XFC550-3P4-160KG-NEN-20 |
| Model | W | H | D | w | h | h1 | h2 | d | W1 | Fixing screws | Net Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|
| XFC550-3P4-185KG-NEN-20 | 340 | 1218 | 560 | 200 | 1150 | 1180 | 53 | 545 | 400 | M12 | 210kg / 463.1lb |
| XFC550-3P4-200KG-NEN-20 | |||||||||||
| XFC550-3P4-220KG-NEN-20 | |||||||||||
| XFC550-3P4-250KG-NEN-20 | |||||||||||
| XFC550-3P4-280KG-NEN-20 | |||||||||||
| XFC550-3P4-315KG-NEN-20 | 340 | 1445 | 560 | 200 | 1375 | 1410 | 56 | 545 | 400 | 245kg / 540.2lb | |
| XFC550-3P4-355KG-NEN-20 | |||||||||||
| XFC550-3P4-400KG-NEN-20 | |||||||||||
| XFC550-3P4-450KG-NEN-20 |
Accessories (Optional)
| Image | Expansion type | Model No. | Function | Install port | Install quantity |
|---|---|---|---|---|---|
|
IO expansion card | XFC5-IOC-00 | 5 digital inputs, 1 analog input, 1 relay output, 1 open collector output, and 1 analog output can be added, with CAN interface. | X630 | 1 |
|
Programmable expansion card | XFC5-PLC-00 | Connect with the VFD to form a PLC+VFD combination, compatible with Mitsubishi PLC programming environment. The card has 5 digital inputs, 1 analog input, 2 relay outputs, 1 analog output, and RS485 interface. |
X630 | 1 |
|
Profibus-DP expansion card | XFC5-PFB-00 | It has Profibus-DP communication function, fully supports Profibus-DP protocol, and supports baud rate adaptive function, which allows the VFD to be connected to the Profibus communication network to realize real-time reading of all function codes of the VFD and realize field bus control. | X630 | 1 |
|
CANopen expansion card | XFC5-CAN-00 | The VFD can be connected to the high-speed CAN communication network to realize field bus control. The CANopen expansion card supports Heartbeat protocol, NMT messages, SDO messages, 3 TPDOs, 3 RPDOs, and emergency objects. |
X630 | 1 |
|
Ethercat expansion card | XFC5-ECT-00 | With Ethercat communication function and fully supports the Ethercat protocol, which allows the VFD to be connected to the Ethercat communication network to realize real-time reading of the VFD function code and field bus control. | X630 | 1 |
Frequently Asked Questions (FAQ)
Q1: What motor control parameters and modes are supported by the XFC550 series VFD?
The XFC550 inverter provides four sets of preset motor control parameters for different motors. It supports Open Loop Vector Control (SVC), Closed Loop Vector Control (FOC), and V/f Control.
Q2: Can I install multiple expansion cards simultaneously on the XFC550 VFD?
Yes, the XFC550 series supports the simultaneous installation of two built-in expansion cards: one for function/communication extensions (such as IO, PLC, CANopen, Ethercat, Profibus-DP) and the other for an encoder expansion card.
Q3: What input voltage and frequency range does the XFC550 inverter accommodate?
The standard rated supply voltage is 3-phase 380V to 480V (-15% to +10% allowed fluctuation) with a rated frequency of 50/60Hz (±5% fluctuation allowed).
Q4: How does the XFC550 handle overcurrent and overvoltage situations?
It features high-performance over-current and over-voltage stall control along with a fast current-limiting function to automatically manage current and voltage spikes, minimizing fault shutdowns.
Q5: Is the XFC550 VFD compatible with industrial automation networks?
Yes, through optional expansion cards, the XFC550 seamlessly integrates with industrial fieldbuses including Modbus RS485 (standard), Profibus-DP, CANopen, and Ethercat.
Q6: What is the operating temperature range for the XFC550 series VFD?
The operating ambient temperature ranges from -10°C to +40°C. Operation between 40°C and 50°C is supported with a derating of 1.5% for every 1°C increase in temperature.