China XST260 Smart Low-voltage Soft Starter 220/380/480V for Motors - Suppliers & Factory Direct
Appearance

| Item | Description |
|---|---|
| A | Terminals are on the top of the device, clearly marked, easy and quick to install, and convenient for wiring. |
| B | 3.5-inch large display screen and status indicator screen, dual-screen display. |
| C | Plastic panels improve the safety of the entire machine. |
| D | Detachable keypad can be installed on the control cabinet door. |
| E | Clear status indication and alarm identification; quickly identify device status. |
Basic Parameters
| Control voltage | AC110V - 220V ±15%, 50/60Hz |
| Mains Voltage | AC220V, AC380V, AC480V ± 10% |
| Nominal current | 18A~780A, 20 rated values in total |
| Applicable motor | Squirrel cage AC asynchronous motor |
| Start methods | Voltage ramp start, Current ramp start, Pump start control, Direct start, Kickstart |
| Stop methods | Voltage ramp, Soft stop, Brake, Free stop, Pump stop |
| Logical input | Impedance 1.8 KΩ, Mains voltage +24V |
| Start frequency | No more than 10 times per hour (recommended) |
| IP | ≤55kW, IP00 ≥75kW, IP20 |
| Cooling type | ≤55kW, Natural cooling ≥75kW, Forced air cooling |
| Installation type | Wall mounted |
| Communication method | RS485 (Optional) |
| Environmental condition | When sea altitude is above 2,000m, soft starter should be derated for use. Ambient temperature: -10 ~ +40°C Relative humidity: less than 95% (20°C±5°C) Free of flammable, explosive and corrosive gas or conductive dust. Indoor installation, good ventilation, vibration less than 0.5G |
Features
-
Communication expansion card
Profibus communication expansion card can be built-in.
-
External keypad + extra large screen available
Easily removable keypad for remote operation.
-
Motor preheating
In low-temperature environments, the motor is heated before operation without the need for external heating equipment.
-
More comprehensive motor protection functions
Overvoltage protection, undervoltage protection, overcurrent protection, overload protection, stall protection, bypass fault, thyristor fault, three-phase current imbalance, motor overheating protection, etc.
-
Pump control function
Unique start and stop control for pump loads. The pump starting function reduces the starting current of pump loads; the pump stopping function reduces the water hammer effect.
-
Pump cleaning function
Self-service cleaning of siltation in the pump to prevent overflow, overload and other failures caused by blocked rotor.
-
Fan braking function
Dynamic braking can quickly stop the running load; static braking can bring the running load to a stop state under the action of external force.
-
Low speed operation function
It has the functions of low-speed forward rotation and low-speed reverse rotation, and can adjust the load running direction at low speed before the motor starts normally.
-
Wide supply voltage range
220V-500V main power input voltage.
Model specifications

| Applicable motor power (kW) | Model No. | Rated current (A) | Motor rated current (A) | Size of primary wires (copper wire) | |
|---|---|---|---|---|---|
| standard wiring | Inside delta connection | ||||
| 7.5 | XST260-0018-03 | 18 | 18 | 32 | 4 mm2 |
| 11 | XST260-0024-03 | 24 | 24 | 42 | 6 mm2 |
| 15 | XST260-0030-03 | 30 | 30 | 52 | 10 mm2 |
| 18.5 | XST260-0039-03 | 39 | 39 | 68 | 10 mm2 |
| 22 | XST260-0045-03 | 45 | 45 | 78 | 16 mm2 |
| 30 | XST260-0060-03 | 60 | 60 | 104 | 25 mm2 |
| 37 | XST260-0076-03 | 76 | 76 | 132 | 35 mm2 |
| 45 | XST260-0090-03 | 90 | 90 | 156 | 35 mm2 |
| 55 | XST260-0110-03 | 110 | 110 | 190 | 35 mm2 |
| 75 | XST260-0150-03 | 150 | 150 | 260 | 50 mm2 |
| 90 | XST260-0180-03 | 180 | 180 | 312 | 30×4 copper bar |
| 110 | XST260-0218-03 | 218 | 218 | 378 | 30×4 copper bar |
| 132 | XST260-0260-03 | 260 | 260 | 450 | 30×4 copper bar |
| 160 | XST260-0320-03 | 320 | 320 | 554 | 30×4 copper bar |
| 185 | XST260-0370-03 | 370 | 370 | 640 | 40×5 copper bar |
| 220 | XST260-0440-03 | 440 | 440 | 762 | 40×5 copper bar |
| 250 | XST260-0500-03 | 500 | 500 | 866 | 40×5 copper bar |
| 280 | XST260-0560-03 | 560 | 560 | 969 | 40×5 copper bar |
| 315 | XST260-0630-03 | 630 | 630 | 1090 | 50×8 copper bar |
| 400 | XST260-0780-03 | 780 | 780 | 1350 | 50×8 copper bar |
Standard wiring refers to the delta or star connection of the motor windings, and the thyristor of the soft starter is connected between the power supply and the motor.
Inner delta connection refers to the delta connection of the motor windings, and the thyristor is directly connected in series with the motor winding.
Drawings
| Power range/kW | G | H | I | K | L | M | D | E | F | A/B/C | Net weight/kg |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 7.5 ~ 30 | 160 | 275 | 189 | 140 | 263 | 5.5 | 92 | 66 | 66 | 50 | 5.2 |
| 37 ~ 55 | 5.7 | ||||||||||
| 75 ~ 160 | 285 | 450 | 295 | 240 | 386 | 9 | 174 | 178 | 144 | 50 | 23.3 |
| 185 ~ 280 | 320 | 520 | 320 | 250 | 446 | 9 | 197 | 189 | 146 | 50 | 33.6 |
| 315 ~ 400 | 490 | 744 | 344 | 400 | 620 | 11 | 306 | 220 | 162 | 50 | 64.2 |
7.5kW ~ 55kW
75kW ~ 160kW
185kW ~ 280kW
315kW ~ 400kW
Applications
Belt conveyor

When material jam occurs, the low-speed forward and reverse functions can be used as appropriate to allow the belt conveyor to drive the jammed material back and forth to alleviate system jams.
Fan

Application of dynamic braking function:
Dynamic braking can be used to quickly stop large inertia loads and solve the problem of long shutdown time of large inertia fans.
Application of static braking function:
When the fan rotates due to external wind force, the static braking function can stop the fan first so that it can be started later.
Comprehensive moisture-proof and anti-corrosion solution
Water pump

Unique pump control features:
Pump systems are susceptible to fluid shock and surge during motor starting and stopping. The pump control function can effectively control the load current when the pump starts and stops, extending the pump life.
When starting:
In pump starting mode, the output voltage increases according to the pump load characteristic curve until the output voltage reaches full voltage.
When stopping:
The pump stop curve can effectively slow down the water hammer phenomenon caused by the pump load when it stops.
Application scenarios for pump cleaning:
When the blades are blocked by mud, the starting current of the water pump will be too large, resulting in overcurrent or overload protection. After using the pump cleaning function, the impeller is self-cleaned before the water pump is started to ensure normal pumping.