Leave Your Message

China XPQ Static Var Generator Suppliers - 400V/690V Power Quality Enhancement Factory Solution

The XPQ-Static Var Generator is a cutting-edge solution designed to enhance power quality by effectively compensating for grid reactive power. This product, manufactured in China by leading suppliers, is ideal for various industrial applications. Key features include: - **Rated Voltage**: 400V (±20%) / 690V (±20%) - **Compensation Capacity**: Ranges from 25 to 500kVar - **Adjustable Power Factor**: Targeting a range from -0.99 to 0.99 - **Harmonic Compensation**: Capable of addressing harmonics from the 2nd to the 25th - **Compensation Range**: Includes both perceptual and capacitive reactive power - **Comprehensive Protection Functions**: Equipped with safeguards against grid overvoltage, undervoltage, overcurrent, bus overvoltage, overheating, and current limiting As a trusted factory in China's power management sector, we ensure that our XPQ-Static Var Generator meets the highest quality standards while providing exceptional performance and reliability.

    Features
    1. Compensation ability
    The system can adjust the reactive power output based on site conditions to prevent overcompensation or undercompensation, ensuring a power factor of 0.99.
    2. Fast response
    Fully digital control. The harmonic current detection utilizes an efficient TTA algorithm based on time domain exchange. This enables quick and accurate calculation of the instantaneous value of reactive current, leading to a significant improvement in compensation response time and achieving a full response within 10ms.
    3. High-end quality of core components
    German original IGBT module, three-level topology.
    The control system is comprised of the American TIDSP control chip, as well as ALTERA and CYCLONE 3 series FPGA chips, making it a powerful three-core system.
    Additionally, TI's double-ended high-speed input 12-bit A/D data conversion chip enhances the accuracy and reliability of signal sampling.
    4. Efficient heat dissipation
    The layered heat dissipation design allows for independent air ducts, leading to improved heat dissipation performance and effectively preventing dust and other pollutants from affecting the control system.
    5. Independent fan, detachable
    The fans can be easily disassembled and reassembled independently, enhancing heat dissipation reliability.
    6. Modular design
    Various capacity modules can be installed in any combination to improve the reliability and maintainability of the whole machine.
    7. Human-Machine Interface
    Single module can be equipped with a 5-inch LCD touchscreen, and multiple modules can have an external 7-inch LCD touchscreen.
    It supports real-time monitoring of operating data and online change of control parameters. It is simple to operate and can be equipped with an optional mobile phone APP for remote control.
    Basic Parameters
    Compensation capacity / Kvar 25 30 50 75 100 100
    AC input Rated voltage 400V (±15%) 690V (±15%)
    Working frequency (50±10%) Hz
    Wiring method 3-phase 4-wire or 3-phase 3-wire
    Technical Parameter Filtering capability
    ≥97%;
    Excess capacity is compensated at maximum capacity
    Power consumption ≤3% of rated capacity
    Module expansion capability Up to 10 function modules
    Switching frequency 20kHz
    Circuit topology Three-level
    Compensation range Inductive reactive power and capacitive reactive power can be continuously compensated
    Filter level setting Each harmonic can be individually set, and the ability to selectively eliminate specific harmonics (enhanced SVG) and ordinary SVG without filtering
    Compensation range Inductive reactive power, capacitive reactive power can be continuously compensated
    Compensation range The maximum inrush current Not more than rated current
    Response time 100μs / 10ms
    Protection function Grid overvoltage, undervoltage, overcurrent, bus overvoltage, overheating and current limiting protection, etc., with a delay of 5μs
    Display function
    1. Each voltage and current value, current waveform display;
    2. Total load current value, SVG output total current value display;
    3. Operation mode setting, fault and runtime inquiry.
    Communication Interface RS232, RS485; WIFI and GPRS optional
    Performance Noise <65dB
    Target power factor -0.99 ~ 0.99 adjustable
    Cooling method Forced air cooling
    Ambient temperature -10℃ ~ +40℃
    Storage temperature -20℃ ~ +60℃
    Humidity Maximum Max 95%RH (non-condensing)
    Altitude Altitude ≤1500m, according to GB/T3859.2, the capacity decreases by 1% for every 100M increase
    Protection grade IP20 (other protection grades can be customized)
    Mechanical characteristic Color
    Acrylic black;
    other colors can be customized on request.
    Operating characteristics

    Operating safely and reliably 24/7 without disrupting the normal operation of other system equipment.

    The module has protection measures such as overhumidity, overvoltage, undervoltage, overload and overcurrent, short circuit and system self-diagnosis function.

    If a fault such as a short circuit occurs inside the module, it can protect itself without affecting the external power system.

    If the compensation energy required by the load is greater than the rated compensation energy, it can be output according to the main body capacity and continue to compensate without overloading or causing equipment damage and exiting operation.

    Model Specifications
    XPQ Static Var Generator, 400V690V4js
    Dimensions

    Drawer type

    XPQ Static Var Generator, 400V690V (1)3y4
    Model No. Dimensions(mm)
    W H D w d h Set screw Net weight(kg)
    XPQ - SG - 4L - 030 484 200 640 465 158 610 M6 34
    XPQ - SG - 4L - 050
    XPQ - SG/MG - 4L - 075
    XPQ - SG/MG - 4L - 100 544 250 646 525 180 610 47
    XPQ - MG - 4L - 030 392 200 555 373 158 530 29
    XPQ - MG - 4L - 050 392 200 555 373 158 530 29

    Wall-mounted type

    XPQ Static Var Generator, 400V690V (2)74k
    Model No. Dimensions(mm)
    W H D w d h Set screw Net weight(kg)
    XPQ - SG - 4L - 030 440 657 212 375 633 / M8 35
    XPQ - SG - 4L - 050
    XPQ - SG/MG - 4L - 075
    XPQ - SG/MG - 4L - 100 500 657 262 375 633 / 48
    XPQ - MG - 4L - 030 348 577 208 275 553 / 30
    XPQ - MG - 4L - 050 / 30

    Drawer type (lightweight)

    XPQ Static Var Generator, 400V690V (3)5sg
    Model No. Dimensions(mm)
    W H D w d h Set screw Net weight(kg)
    XPQ - CG - 4L - 030 88 520 420 / 507.6 / M6 15
    XPQ - CG - 4L - 050

    Wall-mounted (lightweight)

    XPQ Static Var Generator, 400V690V (4)lzh
    Model No. Dimensions(mm)
    W H D w d h Set screw Net weight(kg)
    XPQ - CG - 4L - 030 460 473 101.2 350 454 / M8 15
    XPQ - CG - 4L - 050
    Frequently Asked Questions
    What is the compensation response time of the XPQ Static Var Generator?
    The system achieves a rapid response of 100μs and reaches full compensation response within 10ms, driven by full digital control and an efficient TTA algorithm based on time-domain exchange.
    What target power factor can the system achieve?
    The system dynamically regulates reactive power output to prevent both overcompensation and undercompensation, maintaining an adjustable target power factor between -0.99 and 0.99, ensuring an optimal power factor of 0.99.
    What core components are utilized in the control architecture?
    The equipment uses original German IGBT modules with a three-level topology, a three-core architecture featuring an American TI DSP control chip combined with ALTERA and CYCLONE 3 series FPGA chips, and a TI dual-ended high-speed 12-bit A/D data converter.
    How many modules can be expanded in parallel?
    The modular architecture supports parallel expansion for up to 10 functional modules, allowing flexible combinations of capacities to meet application needs and simplify maintenance.
    What installation form factors and dimensions are offered?
    The product is available in standard Drawer type, Wall-mounted type, Drawer type (lightweight), and Wall-mounted (lightweight) configurations, accommodating various cabinet spaces and load capacities.
    What monitoring and communication options are supported?
    Single modules can be fitted with a 5-inch LCD touchscreen, while multi-module systems support an external 7-inch LCD touchscreen. For system integration, RS232 and RS485 interfaces are standard, with optional Wi-Fi, GPRS, and mobile APP remote control.

    Leave Your Message