0102030405
China XFC500 3 Phase VFD Drive for Pumps, 380~480V - Top Suppliers & Factory for Quality Drives
Features
1
Superior motor drive and protection performance
- High-precision motor parameter self-learning function
- High-performance open-loop vector control
- Stable overvoltage, over-current stall control, reducing the number of failures
- Efficient instantaneous power failure protection function
2
High reliability design
- Electromechanical collaborative design to ensure the close cooperation between electronic components and structural parts;
- Accurate thermal simulation design ensures the best heat dissipation efficiency of the product;
- Excellent EMC(Electromagnetic Compatibility)design to reduce harmonic interference;
- More than 100 rigorous system tests to ensure the high performance and high quality of products;
- The temperature rise verification of the whole machine ensures the safe operation of the product.
3
Flexible application
- Multiple application function expansion enhances the applicability of the product;
- Rich communication expansion to meet the networking control requirements of different fieldbuses;
- High-performance LED keyboard, shuttle knob, clear display and easy operation;
- Support common DC bus and DC power supply;
- EMC safety capacitor grounding (optional);
- Various installation methods - please refer to the product installation diagram for details.
Basic Parameters
| Item | Parameter | |
|---|---|---|
| Power supply | Rated supply voltage | 3 phase 380V ~ 480V |
| Allowed voltage fluctuations | -15%~+10% | |
| Rated supply frequency | 50/60Hz | |
| Allowed Frequency Fluctuations | ±5% | |
| Output | Max output voltage | Three-phase 380V~480V Go after the input voltage |
| Max Output frequency | 500Hz | |
| Carrier Frequency | 0.5 ~ 16kHz (automatic adjustment according to the temperature, and the adjustment range differs for different models ) | |
| Overload capacity | Type G: 150% rated current 60s; 180% rated current 3s. Type P: 120% rated current 60s; 150% rated current 3s. |
|
| Basic Functions | Frequency setting resolution | Digital setting: 0.01Hz Analog setting: max frequency × 0.025% |
| Control Mode | Open Loop Vector Control (SVC) V/F Control |
|
| Pull-in torque | 0.3Hz/150%(SVC) | |
| Speed range | 1 : 200(SVC) | |
| Speed Stabilizing accuracy | ±0.5%(SVC) | |
| Torque boost | Automatic torque boost Manual torque increase 0.1% ~ 30.0% |
|
| V/F Curve | Three ways: linear type; multi-point type; N-th power V/F curve (n=1.2, 1.4, 1.6, 1.8, 2) |
|
| Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration; Four kinds of acceleration and deceleration time. Adjustable range 0.0~6500.0S |
|
| DC braking | Frequency of DC braking: 0.00Hz ~ max frequency Braking time: 0.0s ~ 36.0s Braking action current value: 0.0% ~ 100.0% |
|
| Jogging control | Jogging frequency range:0.00Hz ~ 50.00Hz Jog acceleration- deceleration time:0.0s ~ 6500.0s |
|
| Simple PLC, multi-stage speed operation | Up to 16-stage speed operation via built-in PLC or control terminal | |
| Built-in PID | Implementing closed-loop control in process control applications | |
| Overvoltage and overcurrent stall control | Automatically limit current and voltage during operation to prevent fault shutdown due to frequent over-current and over-voltage | |
| Fast current limiting function | Reduce overcurrent fault shutdown to ensure the normal operation of the frequency converter | |
| Control interface | Digital input | 5 multi-function digital inputs. One of which supports max 100kHz pulse input function |
| Analog input | 2 analog inputs. Both supporting 0 ~ 10V or 0 ~ 20mA analog input, switch voltage or current input via jumper |
|
| Digital output | 2 open-collector digital outputs. One of which supports max 100KHz square wave output |
|
| Analog output | 1 analog output. Supporting 0 ~ 10V or 0 ~ 20mA analog output, switch voltage or current output via jumper |
|
| Relay output | 1-channel relay output, including 1 normally open contact, 1 normally closed contact | |
| Standard communication interface | 1 channel RS485 communication interface | |
| Expansion interface | Function expansion interface | Connectable to IO expansion card, PLC programmable expansion card, etc. |
| Operation panel | LED digital display | 5-digit display of parameters and settings |
| Indicator light | 4 status indications, 3 unit indications | |
| Button’s Function | 5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00 | |
| Shuttle Knob | Add, minus and confirm | |
| Parameter copy | Fast upload and download parameters | |
| Protective function | Basic protection | Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions |
| Environment | Operation condition | Indoor, no conductive dust and oil, etc. |
| Operating ambient temperature | -10°C ~ +40°C (40°C ~ 50°C, derate 1.5% for every 1°C increase in temperature) | |
| Humidity | Less than 95% RH, no condensation | |
| Operating altitude | No derating below 1000m, derate by 1% for every 100m elevation above 1000m | |
| Ambient temperature for Storage | -20℃ ~ +60℃ | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Installation method | Wall-mounted or flush-mounted installation in the cabinet (Need to choose the appropriate installation accessories) | |
| IP degree of protection | IP20 | |
Model Specifications
| Model No. | Motor power / kW | Rated input Capacity / kVA | Rated input current / A | Rated output current / A |
|---|---|---|---|---|
| XFC500-3P4-1k50G-BEN-20 | 1.5G | 3.2 | 4.8 | 4 |
| XFC500-3P4-2k20G-BEN-20 | 2.2G | 4.5 | 6.8 | 5.6 |
| XFC500-3P4-4k00G-BEN-20 | 4G | 7.9 | 12 | 9.7 |
| XFC500-3P4-5K50G/7K50P-BEN-20 | 5.5G | 11 | 16 | 13 |
| 7.5P | 14 | 21 | 17 | |
| XFC500-3P4-7K50G/11k0P-BEN-20 | 7.5G | 14 | 21 | 17 |
| 11P | 20 | 30 | 25 | |
| XFC500-3P4-11K0G/15K0P-BEN-20 | 11G | 20 | 30 | 25 |
| 15P | 27 | 41 | 33 | |
| XFC500-3P4-15K0G/18K5P-BEN-20 | 15G | 27 | 41 | 33 |
| 18.5P | 33 | 50 | 40 | |
| XFC500-3P4-18K5G/22K0P-BEN-20 | 18.5G | 33 | 50 | 40 |
| 22P | 38 | 57 | 45 | |
| XFC500-3P4-22K0G/30K0P-BEN-20 | 22G | 38 | 57 | 45 |
| 30P | 51 | 77 | 61 | |
| XFC500-3P4-30K0G/37K0P-NEN-20 | 30G | 51 | 77 | 61 |
| 37P | 62 | 94 | 74 | |
| XFC500-3P4-37K0G/45K0P-NEN-20 | 37G | 62 | 94 | 74 |
| 45P | 75 | 114 | 90 | |
| XFC500-3P4-45K0G/55K0P-NEN-20 | 45G | 75 | 114 | 90 |
| 55P | 91 | 138 | 109 | |
| XFC500-3P4-55K0G/75K0P-NEN-20 | 55G | 91 | 138 | 109 |
| 75P | 123 | 187 | 147 | |
| XFC500-3P4-75K0G/90K0P-NEN-20 | 75G | 123 | 187 | 147 |
| 90P | 147 | 223 | 176 | |
| XFC500-3P4-90K0G/110KP-NEN-20 | 90G | 147 | 223 | 176 |
| 110P | 179 | 271 | 211 | |
| XFC500-3P4-110KG/132KP-NEN-20 | 110G | 179 | 271 | 211 |
| 132P | 200 | 303 | 253 | |
| XFC500-3P4-132KG/160KP-NEN-20 | 132G | 167 | 253 | 253 |
| 160P | 201 | 306 | 303 | |
| XFC500-3P4-160KG/185KP-NEN-20 | 160G | 201 | 306 | 303 |
| 185P | 233 | 353 | 350 | |
| XFC500-3P4-185KG/200KP-NEN-20 | 185G | 233 | 353 | 350 |
| 200P | 250 | 380 | 378 | |
| XFC500-3P4-200KG/220KP-NEN-20 | 200G | 250 | 380 | 378 |
| 220P | 275 | 418 | 416 | |
| XFC500-3P4-220KG/250KP-NEN-20 | 220G | 275 | 418 | 416 |
| 250P | 312 | 474 | 467 | |
| XFC500-3P4-250KG/280KP-NEN-20 | 250G | 312 | 474 | 467 |
| 280P | 350 | 531 | 522 | |
| XFC500-3P4-280KG/315KP-NEN-20 | 280G | 350 | 531 | 522 |
| 315P | 393 | 597 | 588 | |
| XFC500-3P4-315KG/355KP-NEN-20 | 315G | 393 | 597 | 588 |
| 355P | 441 | 669 | 659 | |
| XFC500-3P4-355KG/400KP-NEN-20 | 355G | 441 | 669 | 659 |
| 400P | 489 | 743 | 732 | |
| XFC500-3P4-400KG/450KP-NEN-20 | 400G | 489 | 743 | 732 |
| 450P | 550 | 835 | 822 | |
| XFC500-3P4-450KG-NEN-20 | 450G | 550 | 835 | 822 |
Dimensions
| Model | W | H | D | w | h | h1 | d | t | Screws | Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC500-3P4-1K50G-BEN-20 XFC500-3P4-2K20G-BEN-20 XFC500-3P4-4K00G-BEN-20 |
110 | 228 | 177 | 75 | 219 | 200 | 172 | 1.5 | M5 | 2.5kg / 5.5lb |
| Model | W | H | D | w | h | h1 | d | t | Screws | Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC500-3P4-5K50G-BEN-20 XFC500-3P4-7K50G-BEN-20 |
140 | 268 | 185 | 100 | 259 | 240 | 180 | 1.5 | M5 | 3.2kg / 7.1lb |
| XFC500-3P4-11K0G-BEN-20 XFC500-3P4-15K0G-BEN-20 |
170 | 318 | 225 | 125 | 309 | 290 | 220 | 5kg / 11lb | ||
| XFC500-3P4-18K5G-BEN-20 XFC500-3P4-22K0G-BEN-20 |
190 | 348 | 245 | 150 | 339 | 320 | 240 | 6kg / 13.2lb |
| Model | W | H | D | w | h | h1 | d | t | Screws | Weight |
|---|---|---|---|---|---|---|---|---|---|---|
| XFC500-3P4-30K0G-BEN-20 XFC500-3P4-37K0G-BEN-20 |
260 | 500 | 260 | 200 | 478 | 450 | 255 | 1.5 | M6 | 17kg / 37.5lb |
| XFC500-3P4-45K0G-BEN-20 XFC500-3P4-55K0G-BEN-20 |
295 | 570 | 307 | 200 | 550 | 520 | 302 | 2 | M8 | 22kg / 48.5lb |
| XFC500-3P4-75K0G-BEN-20 XFC500-3P4-90K0G-BEN-20 XFC500-3P4-110KG-BEN-20 |
350 | 661 | 350 | 250 | 634 | 611 | 345 | 2 | M10 | 48kg / 105.8lb |
| XFC500-3P4-132KG-BEN-20 XFC500-3P4-160KG-BEN-20 |
450 | 850 | 355 | 300 | 824 | 800 | 350 | 2 | M10 | 91kg / 200.7lb |
| Model | W | H | D | w | h | h1 | h2 | d | W1 | Screws | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|
| XFC500-3P4-185KG-BEN-20 XFC500-3P4-200KG-BEN-20 XFC500-3P4-220KG-BEN-20 XFC500-3P4-250KG-BEN-20 XFC500-3P4-280KG-BEN-20 |
340 | 1218 | 560 | 200 | 1150 | 1180 | 53 | 545 | 400 | M12 | 210kg / 463.1lb |
| XFC500-3P4-315KG-BEN-20 XFC500-3P4-355KG-BEN-20 XFC500-3P4-400KG-BEN-20 XFC500-3P4-450KG-BEN-20 |
340 | 1445 | 560 | 200 | 1375 | 1410 | 56 | 545 | 400 | 245kg / 540.2lb |
Accessories (Optional)
| Image | Expansion type | Model No. | Function | Install port | Install qty |
|---|---|---|---|---|---|
|
IO expansion card | XFC5-IOC-00 | 5 digital inputs, 1 analog input, 1 relay output, 1 open collector output, and 1 analog output can be added, with CAN interface. | X630 | 1 |
|
Programmable expansion card | XFC5-PLC-00 | Connect with the VFD to form a PLC+VFD combination, compatible with Mitsubishi PLC programming environment. The card has 5 digital inputs, 1 analog input, 2 relay outputs, 1 analog output, and RS485 interface. | X630 | 1 |
|
Profibus-DP expansion card | XFC5-PFB-00 | It has Profibus-DP communication function, fully supports Profibus-DP protocol, and supports baud rate adaptive function, which allows the VFD to be connected to the Profibus communication network to realize real-time reading of all function codes of the VFD and realize field bus control. | X630 | 1 |
|
CANopen expansion card | XFC5-CAN-00 | The VFD can be connected to the high-speed CAN communication network to realize field bus control. The CANopen expansion card supports Heartbeat protocol, NMT messages, SDO messages, 3 TPDOs, 3 RPDOs, and emergency objects. | X630 | 1 |
|
Ethercat expansion card | XFC5-ECT-00 | With Ethercat communication function and fully supports the Ethercat protocol, which allows the VFD to be connected to the Ethercat communication network to realize real-time reading of the VFD function code and field bus control. | X630 | 1 |
Frequently Asked Questions (FAQ)
What is the input voltage range and frequency supported by the XFC500 VFD?
The XFC500 supports a 3-phase rated supply voltage of 380V to 480V with allowed voltage fluctuations of -15% to +10%. The rated supply frequency is 50/60Hz with allowed frequency fluctuations of ±5%.
What control modes are available in the XFC500 series?
The drive features two primary control modes: Open Loop Vector Control (SVC) and standard V/F Control, allowing high-precision motor parameter self-learning and flexible operations.
What is the overload capacity of the Type G and Type P models?
Type G (Heavy Duty) supports 150% rated current for 60 seconds and 180% rated current for 3 seconds. Type P (Normal Duty) supports 120% rated current for 60 seconds and 150% rated current for 3 seconds.
What communication and expansion cards can be added to the XFC500?
The XFC500 features an X630 installation port that supports optional expansion cards, including IO expansion cards, Programmable PLC cards, Profibus-DP cards, CANopen cards, and Ethercat communication cards.
What are the environmental limits for operating the XFC500?
It is designed for indoor installation without conductive dust or oil. The operating temperature range is -10°C to +40°C (derating 1.5% per 1°C up to 50°C), with relative humidity less than 95% RH (non-condensing) and altitudes below 1000m without derating.

