0102030405
China GCS Low-Voltage Switchgear Drawer Type - Reliable Suppliers & Factory with High Breaking Capacity
Product Description
GCS switchgear is a versatile low-voltage power distribution device commonly utilized for power distribution, centralized motor control, and reactive power compensation in power generation and supply systems.
This low-voltage withdrawable switchgear is designed for economy, rationality, and reliability. It features high breaking and making abilities, good dynamic and thermal stability, and flexibility.
The main structure of GCS is similar to that of MNS, with the main busbar at the rear. Unlike the MNS, GCS utilizes a 20mm drawer modulus (25mm in MNS), and the drawer features a propulsion mechanism for easier and more flexible operation.
- G -- Enclosed cabinet
- C -- Draw out
- S -- SenYuan Electric System
Basic Parameters
| Main circuit rated voltage (V) | AC380 400 600 | |
| Auxiliary circuit rated voltage (V) | AC220 380 400 | |
| Rated frequency (Hz) | 50(60) | |
| Rated insulation voltage (V) | 600 1000 | |
| Rated current (A) | Horizontal busbar | ≤4000 |
| vertical busbar | 1000 | |
| Busbar rated short-time withstand current (KA/1s) | 50-80 | |
| Busbar rated peak withstand current (KA/0.1s) | 105 176 | |
| Power frequency test voltage (V/min) | The main circuit | 2500 |
| Auxiliary circuit | 1760 | |
| Busbar | 3-phase 4-wire | A、B、C、PEN |
| 3-phase 5-wire | A、B、C、PE、N | |
| Protection class | Ip30 Ip40 | |
Installation Environment
- The ambient air temperature should not be higher than +40℃ and not lower than -5℃. The average temperature within 24 hours shall not be higher than +35℃;
- Indoor installation and use, the altitude of the use site shall not exceed 2000m;
- The relative humidity of the surrounding air should not exceed 50% when the maximum temperature is +40°C. However, higher relative humidity levels are allowed at lower temperatures. Consider the impact of occasional condensation caused by temperature changes, for instance, 90% at +20°C.
- When installing the equipment, ensure that the angle with the vertical plane does not exceed 5%. Choose a location with minimal vibration and where electrical components are not susceptible to corrosion.
- Users can negotiate with the manufacturer if they have special requirements.
Frequently Asked Questions (FAQ)
What are the primary applications of GCS switchgear?
GCS switchgear is widely used for power distribution, centralized motor control, and reactive power compensation in power generation and supply systems.
What is the key mechanical difference between GCS and MNS switchgear?
While both have the main busbar at the rear, GCS features a 20mm drawer modulus (compared to 25mm in MNS) and uses a propulsion mechanism for easier and more flexible operation.
What is the rated insulation voltage of the GCS system?
The GCS switchgear supports a rated insulation voltage ranging from 600V up to 1000V.
What is the allowable temperature range for GCS switchgear installation?
The ambient air temperature must be between -5℃ and +40℃, with a 24-hour average temperature not exceeding +35℃.
Are there altitude restrictions for installing this switchgear?
Yes, GCS switchgear is designed for indoor installation at altitudes not exceeding 2000 meters above sea level.
What protection classes does GCS switchgear support?
It supports IP30 and IP40 protection classes, offering reliable protection against solid foreign objects.