Leave Your Message

China CMC-MX Soft Starter with Internal Bypass Contactor for 380V Motors - Suppliers & Factory Direct

Introducing the CMC-MX Series Motor Soft Starters, the ideal solution for achieving a smooth start and stop for standard squirrel cage asynchronous motors. Manufactured in China, our soft starters are designed to enhance your motor performance while minimizing electrical shock during operation, Key Features:, ● Experience a seamless motor start and stop process, enhancing safety and performance, ● Our soft starters come with a built-in bypass contactor, saving valuable installation space and simplifying setup, ● With a wide range of current and voltage settings, as well as torque control features, these soft starters are adaptable to various loads, making them perfect for diverse industrial applications, ● Equipped with multiple protection features to ensure reliable operation and longevity, ● Supports Modbus-RTU communication for easy integration into your control systems, Applicable Motor: Squirrel Cage AC Asynchronous (Induction) Motor, Mains Voltage: AC 380V, Power Range: 7.5 ~ 280 kW, As a leading factory and supplier in the industry, we prioritize quality and performance in our products, making the CMC-MX Series the perfect choice for your motor starting needs

    Features

    Various starting methods

    Users can select current limit start, voltage ramp start, and can apply programmable kick start and start current limit in each mode. Meet the needs of the site and achieve a good starting effect.

    High reliability

    The high-performance microprocessor digitizes the signals in the control system, avoiding the excessive adjustment of the analog circuits in the past, thereby obtaining accuracy and execution speed.

    Strong anti-interference

    All external control signals are optically isolated, and different anti-noise levels are set to adapt to use in special industrial environments.

    Simple adjustment method

    The control system has a wide range of applications, the mode adjustment is simple and intuitive, and various functional options can be used to match various control objects.

    Optimized structure

    The unique compact internal structure design is particularly convenient for users to integrate into the existing system, saving the cost of current transformers and bypass contactors for users.

    Power frequency can be set

    The power frequency 50/60Hz is set by parameters, which is convenient for users to use.

    Analog output

    4-20mA current output function, user-friendly.

    MODBUS-RTU communication

    During network communication, 32 devices can be connected. Users can achieve the purpose of automatic communication by setting the baud rate and communication address. The communication address setting range is 1-32, and the factory default value is 1. The communication baud rate setting range is: 0, 2400; 1, 4800; 2, 9600; 3, 19200; the factory value is 2 (9600).

    Perfect protection function

    A variety of motor protection functions (such as overcurrent, input/output phase loss, thyristor short circuit, overheat protection, leakage detection, electronic thermal overload, internal contactor fault, phase current imbalance, etc.) Not damaged during operation.

    Easy maintenance

    The monitoring signal coding system composed of 4-digit digital display monitors the working conditions of the system equipment 24 hours a day, and provides fast fault diagnosis at the same time.

    Basic Parameters

    Applicable motor type Ordinary squirrel cage AC asynchronous motor
    Rated control supply voltage AC110V to AC220V+15%
    Supply frequency 50/60Hz
    Rated operation voltage Standard wiring AC380V
    Internal delta wiring AC380V±30%
    Nominal current 18A~560A, 18 rated values in total
    Applicable motor Ordinary squirrel cage AC asynchronous motor
    Start mode Current-limited soft-start,
    Voltage ramp start.
    Stop mode Free stop,
    Soft stop
    Logical input Impedance 1.8 KΩ, power supply +15V
    Start frequency Frequent or infrequent startup can be done, it is recommended that the number of startups per hour does not exceed 10 times
    Protective function Phase failure, overcurrent, short circuit, SCR protection, overheating, underload, phase current imbalance, wiring, internal fault, etc.
    IP degree of protection IP00
    Cooling system Natural cooling or forced air cooling
    Installation type Wall mounted-vertical installation
    Installation Environment When sea altitude is above 2,000m, soft starter should be derated for use.
    Ambient temperature: -25°C to +45°C
    Relative humidity: less than 95% (20°C±5°C)
    Free of flammable, explosive and corrosive gas or conductive dust.
    Indoor installation, good ventilation, vibration less than 0.5G

    Model Specifications

    product-description1r97
    Model No. Rated Current (A) Applicable motor power (kW) Size & Net weight
    CMC-008/3-MX 18 7.5 173*275*192mm,
    5.6kg
    CMC-011/3-MX 24 11
    CMC-015/3-MX 30 15
    CMC-018/3-MX 39 18.5
    CMC-022/3-MX 45 22
    CMC-030/3-MX 60 30
    CMC-037/3-MX 76 37
    CMC-045/3-MX 90 45
    CMC-055/3-MX 110 55
    CMC-075/3-MX 150 75 285*450*305mm,
    25.1kg
    CMC-090/3-MX 180 90
    CMC-110/3-MX 218 110
    CMC-132/3-MX 260 132
    CMC-160/3-MX 320 160
    CMC-185/3-MX 370 185 320*523*330mm,
    34.5kg
    CMC-220/3-MX 440 220
    CMC-250/3-MX 500 250
    CMC-280/3-MX 560 280

    Dimensions

    Power range Size (mm)
    G H I K L M E D A/B/C
    8 ~ 55 kW 173 275 192 133 250 7 90 86 50
    75 ~ 160 kW 285 450 305 230 390 9 170 158 50
    185 ~ 280 kW 320 523 330 270 415 9 195 158 50
    product-description2xyv
    55kW and below
    product-description3l9r
    75kW ~ 160kW
    product-description4nh8
    185kW ~ 280kW
    product-description5b2g

    Basic Settings of Different Applications

    (following settings are for reference only)
    Load type Initial voltage (%) Start ramp time (s) Stop ramp time (s) Current limit ILIM
    Foreship propeller 25 10 0 2.5
    Centrifugal fan 25 20 0 3.5
    Centrifugal pump 25 6 6 3
    Piston compressor 25 15 0 3
    Hoisting machinery 30 15 6 3.5
    Mixer 40 15 0 3.5
    Crusher 30 15 6 3.5
    Screw compressor 20 15 0 3.5
    Spiral conveyor belt 25 10 6 3.5
    No-load motor 25 10 0 2.5
    Conveyor belt 25 15 10 3.5
    Heat pump 25 15 6 3
    Escalator 25 10 0 3
    Air pump 25 10 0 2.5

    Frequently Asked Questions (FAQ)

    Q What starting modes does this soft starter support?

    This soft starter supports current-limited soft-start and voltage ramp start modes. Users can also apply programmable kick start and start current limit in each mode to meet specific site requirements.

    Q What built-in protection functions are provided?

    It features comprehensive motor protection functions, including phase failure, overcurrent, thyristor short circuit, overheating, underload, phase current imbalance, electronic thermal overload, and internal contactor fault protection.

    Q Can this soft starter be controlled via network communication?

    Yes, it supports MODBUS-RTU communication. You can connect up to 32 devices in a network and set the communication address from 1 to 32 and choose baud rates ranging from 2400 to 19200 bps.

    Q Are there any specific installation environment requirements?

    It should be wall-mounted vertically indoors in a well-ventilated area. The ambient temperature must be between -25°C and +45°C, relative humidity below 95%, and vibration less than 0.5G. Additionally, it must be free of flammable, explosive, or corrosive gases.

    Q How does the soft starter handle high-altitude operation?

    For installations where the sea altitude is above 2,000 meters, the soft starter must be derated for safe and proper operation.

    Q What is the recommended maximum startup frequency?

    While the system is capable of handling frequent or infrequent startups, it is recommended that the number of startups does not exceed 10 times per hour.

    Leave Your Message