Leave Your Message

China CMC-MX Soft Starter with Internal Bypass Contactor 380V - Power Range 7.5 to 280 kW | Suppliers & Factory

The CMC-MX series motor soft starters are designed for the smooth start and stop of standard squirrel cage asynchronous motors, making them an ideal choice for various applications in China. These soft starters provide a gentle ramp-up and ramp-down of motor speed, effectively preventing electrical shocks and ensuring operational safety.

,

Key features of the CMC-MX series include:

,

● Smoothly start and stop motors to minimize electrical shock risks;

,

● Built-in bypass contactor saves space and simplifies installation, making it a preferred option among suppliers and factories;

,

● A wide range of current and voltage settings alongside torque control, allowing adaptability to various load conditions;

,

● Equipped with multiple protection features for enhanced reliability;

,

● Supports Modbus-RTU communication for seamless integration into existing systems.

,

This motor soft starter is specifically applicable for squirrel cage AC asynchronous (induction) motors, operating at a mains voltage of AC 380V, and supports a power range of 7.5 to 280 kW, catering to the diverse needs of industries throughout China.

    Features

    Various starting methods
    Users can select current limit start, voltage ramp start, and can apply programmable kick start and start current limit in each mode. Meet the needs of the site and achieve a good starting effect.
    High reliability
    The high-performance microprocessor digitizes the signals in the control system, avoiding the excessive adjustment of the analog circuits in the past, thereby obtaining accuracy and execution speed.
    Strong anti-interference
    All external control signals are optically isolated, and different anti-noise levels are set to adapt to use in special industrial environments.
    Simple adjustment method
    The control system has a wide range of applications, the mode adjustment is simple and intuitive, and various functional options can be used to match various control objects.
    Optimized structure
    The unique compact internal structure design is particularly convenient for users to integrate into the existing system, saving the cost of current transformers and bypass contactors for users.
    Power frequency can be set
    The power frequency 50/60Hz is set by parameters, which is convenient for users to use.
    Analog output
    4-20mA current output function, user-friendly.
    MODBUS-RTU communication
    During network communication, 32 devices can be connected. Users can achieve the purpose of automatic communication by setting the baud rate and communication address. The communication address setting range is 1-32, and the factory default value is 1. The communication baud rate setting range is: 0, 2400; 1, 4800; 2, 9600; 3, 19200; the factory value is 2 (9600).
    Perfect protection function
    A variety of motor protection functions (such as overcurrent, input/output phase loss, thyristor short circuit, overheat protection, leakage detection, electronic thermal overload, internal contactor fault, phase current imbalance, etc.) Not damaged during operation.
    Easy maintenance
    The monitoring signal coding system composed of 4-digit digital display monitors the working conditions of the system equipment 24 hours a day, and provides fast fault diagnosis at the same time.

    Basic Parameters

    Applicable motor type Ordinary squirrel cage AC asynchronous motor
    Rated control supply voltage AC110V to AC220V+15%
    Supply frequency 50/60Hz
    Rated operation voltage Standard wiring AC380V
    Internal delta wiring AC380V±30%
    Nominal current 18A~560A, 18 rated values in total
    Applicable motor Ordinary squirrel cage AC asynchronous motor
    Start mode Current-limited soft-start,
    Voltage ramp start.
    Stop mode Free stop,
    Soft stop
    Logical input Impedance 1.8 KΩ, power supply +15V
    Start frequency Frequent or infrequent startup can be done, it is recommended that the number of startups per hour does not exceed 10 times
    Protective function Phase failure, overcurrent, short circuit, SCR protection, overheating, underload, phase current imbalance, wiring, internal fault, etc.
    IP degree of protection IP00
    Cooling system Natural cooling or forced air cooling
    Installation type Wall mounted-vertical installation
    Installation Environment When sea altitude is above 2,000m, soft starter should be derated for use.
    Ambient temperature: -25°C to +45°C
    Relative humidity: less than 95% (20°C±5°C)
    Free of flammable, explosive and corrosive gas or conductive dust.
    Indoor installation, good ventilation, vibration less than 0.5G

    Model Specifications

    product-description1r97
    Model No. Rated Current (A) Applicable motor power (kW) Size & Net weight
    CMC-008/3-MX 18 7.5 173*275*192mm,
    5.6kg
    CMC-011/3-MX 24 11
    CMC-015/3-MX 30 15
    CMC-018/3-MX 39 18.5
    CMC-022/3-MX 45 22
    CMC-030/3-MX 60 30
    CMC-037/3-MX 76 37
    CMC-045/3-MX 90 45
    CMC-055/3-MX 110 55
    CMC-075/3-MX 150 75 285*450*305mm,
    25.1kg
    CMC-090/3-MX 180 90
    CMC-110/3-MX 218 110
    CMC-132/3-MX 260 132
    CMC-160/3-MX 320 160
    CMC-185/3-MX 370 185 320*523*330mm,
    34.5kg
    CMC-220/3-MX 440 220
    CMC-250/3-MX 500 250
    CMC-280/3-MX 560 280

    Dimensions

    Power range Size (mm)
    G H I K L M E D A/B/C
    8 ~ 55 kW 173 275 192 133 250 7 90 86 50
    75 ~ 160 kW 285 450 305 230 390 9 170 158 50
    185 ~ 280 kW 320 523 330 270 415 9 195 158 50
    product-description2xyv
    55kW and below
    product-description3l9r
    75kW ~ 160kW
    product-description4nh8
    185kW ~ 280kW
    product-description5b2g

    Basic Settings of Different Applications

    (following settings are for reference only)
    Load type Initial voltage (%) Start ramp time (s) Stop ramp time (s) Current limit ILIM
    Foreship propeller 25 10 0 2.5
    Centrifugal fan 25 20 0 3.5
    Centrifugal pump 25 6 6 3
    Piston compressor 25 15 0 3
    Hoisting machinery 30 15 6 3.5
    Mixer 40 15 0 3.5
    Crusher 30 15 6 3.5
    Screw compressor 20 15 0 3.5
    Spiral conveyor belt 25 10 6 3.5
    No-load motor 25 10 0 2.5
    Conveyor belt 25 15 10 3.5
    Heat pump 25 15 6 3
    Escalator 25 10 0 3
    Air pump 25 10 0 2.5

    Frequently Asked Questions (FAQ)

    Q1: What starting modes does this soft starter support?
    This soft starter supports current-limited soft-start and voltage ramp start. Users can also apply programmable kick start and start current limit in each mode to meet specific site requirements.
    Q2: What protection functions are built into the soft starter?
    It features comprehensive motor protection functions, including phase failure, overcurrent, short circuit, SCR protection, overheating, underload, phase current imbalance, wiring issues, and internal contactor faults.
    Q3: Can this soft starter be used in high-altitude environments?
    Yes, it can be used at high altitudes. However, if the installation site is above 2,000 meters, the soft starter should be derated for safe operation.
    Q4: Does the starter support network communication?
    Yes, it supports MODBUS-RTU communication. Up to 32 devices can be connected in network communication, and users can adjust the communication address (1-32) and baud rate (2400 to 19200 bps).
    Q5: What are the environmental temperature and humidity limits for installation?
    The soft starter is designed for indoor vertical wall-mounted installation. The ambient temperature should remain between -25°C and +45°C, with a relative humidity of less than 95% (at 20°C±5°C). The environment should also be free of flammable, explosive, or corrosive gases.
    Q6: What rated control supply voltage is required?
    The rated control supply voltage is AC110V to AC220V +15% with a supply frequency of 50/60Hz, making it highly adaptable to various industrial power grids.

    Leave Your Message