Basic Parameters
| Model type | CFV9000A 2-quadrant | CFV9000A 4-quadrant | |
| Applied motor power (kW) | 200kW-12000kW | 200kW-2000kW | |
| 4-pole motor is the standard, 6-12-pole motor is selected according to current | |||
| Rated output | Rated power (kW) | 200kW-12000kW | 200kW-2000kW |
| Rated current (A) | Rated current of motor rated voltage | ||
| Overload capacity | 105% continuous, 130% allow 1 minute, 150% allow 3 seconds, 180% immediate protection | 150% continuous, 180% allow 1 minute, 250% immediate protection | |
| Output voltage (kV) | Three-phase: 0-6kV, (0-10kV) | ||
| Waveform | Multiplexed SPWM sine wave | ||
| Input voltage | Phase, Frequency, Voltage | Three phase, 50Hz, 6kV(10kV) | |
| Allowed volatility | Voltage: -10%~+10% | Frequency: ±5% -15%~-35% derating for continuous operation |
||
| Basic Performance | Start frequency | 0-10Hz can be set | |
| Accuracy | Analog setting: less than 0.3% of max frequency setting value (25±10°C) Digital setting: less than 0.1% of max frequency setting value (-10 to +50°C) |
||
| Resolution | Analog setting: 1/2000 of the maximum frequency setting value Digital setting: 0.01HZ (below 99.99HZ), 0.1HZ (above 100HZ) |
||
| Efficiency | >98%, at rated output | ||
| Power factor | >0.95 | ||
| Control | Acceleration and deceleration time | 0.01~6000.0S, the acceleration and deceleration time can be set separately | |
| Voltage/Frequency Characteristics | Set by the set V/F curve | ||
| PID | Manually set PID parameters | ||
| Auxiliary function | V/F curve, low frequency compensation, rated current, current protection limit setting | ||
| High voltage isolation | Electromagnetic coupling, multi-channel fiber optic transmission | ||
| Control power input | AC 220V 2kVA | ||
| Run | Run operation | Local control (touch screen, cabinet door switch) operation, remote external control operation, upper computer operation (optional) | |
| Given frequency | Touch screen digital given, multi-speed given, external control analog signal (DC4 ~ 20MA) given | ||
| Running status output | Relay status output, inverter fault, alarm, running/stop and other status indication | ||
| Touch screen | Input/output voltage, input/output current, set value, fault status of each unit, running status, transformer status, bus voltage of each unit, etc. | ||
| Protection | Protection function | Motor overcurrent, whole machine overvoltage, whole machine undervoltage, unit overcurrent, unit overvoltage, unit overheating, unit input phase loss, optical fiber communication failure, etc. | |
| Environment | Applicable places | Indoor, no corrosive or conductive gas, dust, direct sunlight, below 1000 meters above sea level (can be customized for high altitude areas) | |
| Ambient temperature/humidity | -10℃~+40℃ / 20~90%RH without condensation | ||
| Vibration | 5m/s² (below 0.6g) | ||
| Storage temperature | -20 to +65°C (suitable for short-term storage such as transportation) | ||
| Cooling method & Enclosure grade | Forced air cooling / IP31 | ||
Model Specifications
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-6K-F | 315 | 250 | 30 | 1700*1500*1900 | 1900-2410 |
| CFV9000A-350-6K-F | 350 | 280 | 34 | ||
| CFV9000A-400-6K-F | 400 | 315 | 38 | ||
| CFV9000A-450-6K-F | 450 | 355 | 43 | ||
| CFV9000A-500-6K-F | 500 | 400 | 48 | ||
| CFV9000A-560-6K-F | 560 | 450 | 54 | ||
| CFV9000A-630-6K-F | 630 | 500 | 60 | ||
| CFV9000A-700-6K-F | 700 | 560 | 67 | ||
| CFV9000A-790-6K-F | 790 | 630 | 76 | 2200*1700*2120 | 3250-4000 |
| CFV9000A-890-6K-F | 890 | 710 | 85 | ||
| CFV9000A-1000-6K-F | 1000 | 800 | 96 | ||
| CFV9000A-1125-6K-F | 1125 | 900 | 108 | ||
| CFV9000A-1250-6K-F | 1250 | 1000 | 120 | ||
| CFV9000A-1400-6K-F | 1400 | 1120 | 135 | ||
| CFV9000A-1560-6K-F | 1560 | 1250 | 150 | 3300*1700*2420 | 4950-5600 |
| CFV9000A-1750-6K-F | 1750 | 1400 | 168 | ||
| CFV9000A-2000-6K-F | 2000 | 1600 | 192 | 3600*1700*2420 | 6900-7300 |
| CFV9000A-2250-6K-F | 2250 | 1800 | 217 | ||
| CFV9000A-2500-6K-F | 2500 | 2000 | 241 | ||
| CFV9000A-2800-6K-F | 2800 | 2250 | 270 | ||
| CFV9000A-3125-6K-F | 3125 | 2500 | 301 | ||
| CFV9000A-3500-6K-F | 3500 | 2800 | 337 | ||
| CFV9000A-4100-6K-F | 4100 | 3250 | 390 | 4600*1700*2420 | 11750 |
| CFV9000A-5000-6K-F | 5000 | 4000 | 481 | 5900*1700*2420 | 11800 |
| CFV9000A-6250-6K-F | 6250 | 5000 | 601 | 6500*1700*2620 | 12950-13600 |
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-6K-T | 315 | 250 | 30 | 2200*1700*2120 | 2400-4430 |
| CFV9000A-350-6K-T | 350 | 280 | 34 | ||
| CFV9000A-400-6K-T | 400 | 315 | 38 | ||
| CFV9000A-450-6K-T | 450 | 355 | 43 | ||
| CFV9000A-500-6K-T | 500 | 400 | 48 | ||
| CFV9000A-560-6K-T | 560 | 450 | 54 | ||
| CFV9000A-630-6K-T | 630 | 500 | 60 | ||
| CFV9000A-700-6K-T | 700 | 560 | 67 | ||
| CFV9000A-790-6K-T | 790 | 630 | 76 | ||
| CFV9000A-890-6K-T | 890 | 710 | 85 | ||
| CFV9000A-1000-6K-T | 1000 | 800 | 96 | ||
| CFV9000A-1125-6K-T | 1125 | 900 | 108 | ||
| CFV9000A-1250-6K-T | 1250 | 1000 | 120 | ||
| CFV9000A-1400-6K-T | 1400 | 1120 | 135 | 3300*1700*2420 | 5520-5600 |
| CFV9000A-1560-6K-T | 1560 | 1250 | 150 | ||
| CFV9000A-1750-6K-T | 1750 | 1400 | 168 | ||
| CFV9000A-2000-6K-T | 2000 | 1600 | 192 | 3600*1700*2420 | 5850-6090 |
| CFV9000A-2250-6K-T | 2250 | 1800 | 217 | ||
| CFV9000A-2500-6K-T | 2500 | 2000 | 241 | ||
| CFV9000A-3125-6K-T | 3125 | 2500 | 301 | 5550*1700*2420 | 10000 |
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-10K-T | 315 | 250 | 18 | 2800*1700*2120 | 3500-6450 |
| CFV9000A-350-10K-T | 350 | 280 | 20 | ||
| CFV9000A-400-10K-T | 400 | 315 | 23 | ||
| CFV9000A-450-10K-T | 450 | 355 | 26 | ||
| CFV9000A-500-10K-T | 500 | 400 | 29 | ||
| CFV9000A-560-10K-T | 560 | 450 | 32 | ||
| CFV9000A-630-10K-T | 630 | 500 | 36 | ||
| CFV9000A-700-10K-T | 700 | 560 | 40 | ||
| CFV9000A-790-10K-T | 790 | 630 | 45 | ||
| CFV9000A-890-10K-T | 890 | 710 | 51 | ||
| CFV9000A-1000-10K-T | 1000 | 800 | 58 | ||
| CFV9000A-1125-10K-T | 1125 | 900 | 65 | ||
| CFV9000A-1250-10K-T | 1250 | 1000 | 72 | ||
| CFV9000A-1400-10K-T | 1400 | 1120 | 81 | ||
| CFV9000A-1560-10K-T | 1560 | 1250 | 90 | ||
| CFV9000A-1750-10K-T | 1750 | 1400 | 101 | ||
| CFV9000A-2000-10K-T | 2000 | 1600 | 115 | ||
| CFV9000A-2250-10K-T | 2250 | 1800 | 130 | 4100*1700*2420 | 9250-9400 |
| CFV9000A-2500-10K-T | 2500 | 2000 | 144 | ||
| CFV9000A-2800-10K-T | 2800 | 2250 | 162 | ||
| CFV9000A-3125-10K-T | 3125 | 2500 | 180 | ||
| CFV9000A-3500-10K-T | 3500 | 2800 | 202 | 4400*1700*2420 | 9900-9950 |
| CFV9000A-3940-10K-T | 3940 | 3150 | 227 |
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-6K-F | 315 | 250 | 30 | 2700*1500*1900 | 1900-2410 |
| CFV9000A-350-6K-F | 350 | 280 | 34 | ||
| CFV9000A-400-6K-F | 400 | 315 | 38 | ||
| CFV9000A-450-6K-F | 450 | 355 | 43 | ||
| CFV9000A-500-6K-F | 500 | 400 | 48 | ||
| CFV9000A-560-6K-F | 560 | 450 | 54 | ||
| CFV9000A-630-6K-F | 630 | 500 | 60 | ||
| CFV9000A-700-6K-F | 700 | 560 | 67 |
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-10K-F | 315 | 250 | 18 | 2700*1500*1900 | 2160-3100 |
| CFV9000A-350-10K-F | 350 | 280 | 20 | ||
| CFV9000A-400-10K-F | 400 | 315 | 23 | ||
| CFV9000A-450-10K-F | 450 | 355 | 26 | ||
| CFV9000A-500-10K-F | 500 | 400 | 29 | ||
| CFV9000A-560-10K-F | 560 | 450 | 32 | ||
| CFV9000A-630-10K-F | 630 | 500 | 36 | ||
| CFV9000A-700-10K-F | 700 | 560 | 40 | ||
| CFV9000A-790-10K-F | 790 | 630 | 45 | ||
| CFV9000A-890-10K-F | 890 | 710 | 51 | ||
| CFV9000A-1000-10K-F | 1000 | 800 | 58 | ||
| CFV9000A-1125-10K-F | 1125 | 900 | 65 | ||
| CFV9000A-1250-10K-F | 1250 | 1000 | 72 |
Dimensions
Frequently Asked Questions (FAQ)
The CFV9000A 2-quadrant series supports motors from 200kW up to 12000kW, while the 4-quadrant series supports motor capacities from 200kW to 2000kW, typically matched to standard 4-pole motors (or 6-12 pole based on current).
The 2-quadrant model handles standard motoring and directional speed control with overload capabilities up to 150% for 3 seconds, whereas the 4-quadrant model provides continuous 150% overload, enables regenerative braking, and features enhanced overload response up to 250%.
The system accepts three-phase 50Hz 6kV or 10kV with a steady voltage fluctuation range of -10% to +10% and frequency variance of ±5%. Derated continuous operation is supported between -15% and -35% voltage drop.
Comprehensive protection includes motor overcurrent, system overvoltage and undervoltage, power unit overcurrent/overvoltage/overheating, power unit phase loss, and optical fiber communication fault mitigation.
All units use forced air cooling and come standard with an IP31 enclosure rating, suitable for clean indoor environments below 1000m altitude without condensation or corrosive gases.
Operation can be carried out locally via the built-in color touchscreen and door switch, or remotely via DC 4–20mA analog inputs, multi-speed presets, relay feedback, and upper-level computer networks.