0102030405
China CFV9000A Medium-Voltage Variable Frequency Drive Suppliers | 6/10kV Factory Performance Solutions
Basic Parameters
| Model type | CFV9000A 2-quadrant | CFV9000A 4-quadrant | |
| Applied motor power (kW) | 200kW-12000kW | 200kW-2000kW | |
| 4-pole motor is the standard, 6-12-pole motor is selected according to current | |||
| Rated output | Rated power (kW) | 200kW-12000kW | 200kW-2000kW |
| Rated current (A) | Rated current of motor rated voltage | ||
| Overload capacity | 105% continuous, 130% allow 1 minute, 150% allow 3 seconds, 180% immediate protection | 150% continuous, 180% allow 1 minute, 250% immediate protection | |
| Output voltage (kV) | Three-phase: 0-6kV, (0-10kV) | ||
| Waveform | Multiplexed SPWM sine wave | ||
| Input voltage | Phase, Frequency, Voltage | Three phase, 50Hz, 6kV(10kV) | |
| Allowed volatility | Voltage: -10%~+10%, Frequency: ±5%, -15%~-35% derating for continuous operation | ||
| Basic Performance | Start frequency | 0-10Hz can be set | |
| Accuracy |
Analog setting: less than 0.3% of max frequency setting value (25±10°C) Digital setting: less than 0.1% of max frequency setting value (-10 to +50°C) |
||
| Resolution |
Analog setting: 1/2000 of the maximum frequency setting value Digital setting: 0.01HZ (below 99.99HZ), 0.1HZ (above 100HZ) |
||
| Efficiency | >98%, at rated output | ||
| Power factor | >0.95 | ||
| Control | Acceleration and deceleration time | 0.01~6000.0S, the acceleration and deceleration time can be set separately | |
| Voltage/Frequency Characteristics | Set by the set V/F curve | ||
| PID | Manually set PID parameters | ||
| Auxiliary function | V/F curve, low frequency compensation, rated current, current protection limit setting | ||
| High voltage isolation | Electromagnetic coupling, multi-channel fiber optic transmission | ||
| Control power input | AC 220V 2kVA | ||
| Run | Run operation | Local control (touch screen, cabinet door switch) operation, remote external control operation, upper computer operation (optional) | |
| Given frequency | Touch screen digital given, multi-speed given, external control analog signal (DC4 ~ 20MA) given | ||
| Running status output | Relay status output, inverter fault, alarm, running/stop and other status indication | ||
| Touch screen | Input/output voltage, input/output current, set value, fault status of each unit, running status, transformer status, bus voltage of each unit, etc. | ||
| Protection function | Motor overcurrent, whole machine overvoltage, whole machine undervoltage, unit overcurrent, unit overvoltage, unit overheating, unit input phase loss, optical fiber communication failure, etc. | ||
| Environment | Applicable places | Indoor, no corrosive or conductive gas, dust, direct sunlight, below 1000 meters above sea level (can be customized for high altitude areas) | |
| Ambient temperature/humidity | -10℃~+40℃/20~90%RH without condensation | ||
| Vibration | 5m/s² (below 0.6g) | ||
| Storage temperature | -20 to +65°C (suitable for short-term storage such as transportation) | ||
| Cooling method and enclosure protection grade | Forced air cooling/IP31 | ||
Model Specifications

CFV9000A Medium-voltage Variable Frequency Drive
6KV 2-quadrant series (excluding tangent cabinet/connection cabinet)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-6K-F | 315 | 250 | 30 | 1700*1500*1900 | 1900-2410 |
| CFV9000A-350-6K-F | 350 | 280 | 34 | ||
| CFV9000A-400-6K-F | 400 | 315 | 38 | ||
| CFV9000A-450-6K-F | 450 | 355 | 43 | ||
| CFV9000A-500-6K-F | 500 | 400 | 48 | ||
| CFV9000A-560-6K-F | 560 | 450 | 54 | ||
| CFV9000A-630-6K-F | 630 | 500 | 60 | ||
| CFV9000A-700-6K-F | 700 | 560 | 67 | ||
| CFV9000A-790-6K-F | 790 | 630 | 76 | 2200*1700*2120 | 3250-4000 |
| CFV9000A-890-6K-F | 890 | 710 | 85 | ||
| CFV9000A-1000-6K-F | 1000 | 800 | 96 | ||
| CFV9000A-1125-6K-F | 1125 | 900 | 108 | ||
| CFV9000A-1250-6K-F | 1250 | 1000 | 120 | ||
| CFV9000A-1400-6K-F | 1400 | 1120 | 135 | ||
| CFV9000A-1560-6K-F | 1560 | 1250 | 150 | 3300*1700*2420 | 4950-5600 |
| CFV9000A-1750-6K-F | 1750 | 1400 | 168 | ||
| CFV9000A-2000-6K-F | 2000 | 1600 | 192 | 3600*1700*2420 | 6900-7300 |
| CFV9000A-2250-6K-F | 2250 | 1800 | 217 | ||
| CFV9000A-2500-6K-F | 2500 | 2000 | 241 | ||
| CFV9000A-2800-6K-F | 2800 | 2250 | 270 | ||
| CFV9000A-3125-6K-F | 3125 | 2500 | 301 | ||
| CFV9000A-3500-6K-F | 3500 | 2800 | 337 | ||
| CFV9000A-4100-6K-F | 4100 | 3250 | 390 | 4600*1700*2420 | 11750 |
| CFV9000A-5000-6K-F | 5000 | 4000 | 481 | 5900*1700*2420 | 11800 |
| CFV9000A-6250-6K-F | 6250 | 5000 | 601 | 6500*1700*2620 | 12950-13600 |
10KV 2-quadrant series (excluding tangent cabinet/connection cabinet)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-6K-T | 315 | 250 | 30 | 2200*1700*2120 | 2400-4430 |
| CFV9000A-350-6K-T | 350 | 280 | 34 | ||
| CFV9000A-400-6K-T | 400 | 315 | 38 | ||
| CFV9000A-450-6K-T | 450 | 355 | 43 | ||
| CFV9000A-500-6K-T | 500 | 400 | 48 | ||
| CFV9000A-560-6K-T | 560 | 450 | 54 | ||
| CFV9000A-630-6K-T | 630 | 500 | 60 | ||
| CFV9000A-700-6K-T | 700 | 560 | 67 | ||
| CFV9000A-790-6K-T | 790 | 630 | 76 | ||
| CFV9000A-890-6K-T | 890 | 710 | 85 | ||
| CFV9000A-1000-6K-T | 1000 | 800 | 96 | ||
| CFV9000A-1125-6K-T | 1125 | 900 | 108 | ||
| CFV9000A-1250-6K-T | 1250 | 1000 | 120 | ||
| CFV9000A-1400-6K-T | 1400 | 1120 | 135 | 3300*1700*2420 | 5520-5600 |
| CFV9000A-1560-6K-T | 1560 | 1250 | 150 | ||
| CFV9000A-1750-6K-T | 1750 | 1400 | 168 | ||
| CFV9000A-2000-6K-T | 2000 | 1600 | 192 | 3600*1700*2420 | 5850-6090 |
| CFV9000A-2250-6K-T | 2250 | 1800 | 217 | ||
| CFV9000A-2500-6K-T | 2500 | 2000 | 241 | ||
| CFV9000A-3125-6K-T | 3125 | 2500 | 301 | 5550*1700*2420 | 10000 |
10KV 4-quadrant series (excluding tangent cabinet/connection cabinet)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-10K-T | 315 | 250 | 18 | 2800*1700*2120 | 3500-6450 |
| CFV9000A-350-10K-T | 350 | 280 | 20 | ||
| CFV9000A-400-10K-T | 400 | 315 | 23 | ||
| CFV9000A-450-10K-T | 450 | 355 | 26 | ||
| CFV9000A-500-10K-T | 500 | 400 | 29 | ||
| CFV9000A-560-10K-T | 560 | 450 | 32 | ||
| CFV9000A-630-10K-T | 630 | 500 | 36 | ||
| CFV9000A-700-10K-T | 700 | 560 | 40 | ||
| CFV9000A-790-10K-T | 790 | 630 | 45 | ||
| CFV9000A-890-10K-T | 890 | 710 | 51 | ||
| CFV9000A-1000-10K-T | 1000 | 800 | 58 | ||
| CFV9000A-1125-10K-T | 1125 | 900 | 65 | ||
| CFV9000A-1250-10K-T | 1250 | 1000 | 72 | ||
| CFV9000A-1400-10K-T | 1400 | 1120 | 81 | ||
| CFV9000A-1560-10K-T | 1560 | 1250 | 90 | ||
| CFV9000A-1750-10K-T | 1750 | 1400 | 101 | ||
| CFV9000A-2000-10K-T | 2000 | 1600 | 115 | ||
| CFV9000A-2250-10K-T | 2250 | 1800 | 130 | 4100*1700*2420 | 9250-9400 |
| CFV9000A-2500-10K-T | 2500 | 2000 | 144 | ||
| CFV9000A-2800-10K-T | 2800 | 2250 | 162 | ||
| CFV9000A-3125-10K-T | 3125 | 2500 | 180 | ||
| CFV9000A-3500-10K-T | 3500 | 2800 | 202 | 4400*1700*2420 | 9900-9950 |
| CFV9000A-3940-10K-T | 3940 | 3150 | 227 |
6KV All-in-one series (Switch cabinet included)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-6K-F | 315 | 250 | 30 | 2700*1500*1900 | 1900-2410 |
| CFV9000A-350-6K-F | 350 | 280 | 34 | ||
| CFV9000A-400-6K-F | 400 | 315 | 38 | ||
| CFV9000A-450-6K-F | 450 | 355 | 43 | ||
| CFV9000A-500-6K-F | 500 | 400 | 48 | ||
| CFV9000A-560-6K-F | 560 | 450 | 54 | ||
| CFV9000A-630-6K-F | 630 | 500 | 60 | ||
| CFV9000A-700-6K-F | 700 | 560 | 67 |
10KV All-in-one series (Switch cabinet included)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
|---|---|---|---|---|---|
| CFV9000A-315-10K-F | 315 | 250 | 18 | 2700*1500*1900 | 2160-3100 |
| CFV9000A-350-10K-F | 350 | 280 | 20 | ||
| CFV9000A-400-10K-F | 400 | 315 | 23 | ||
| CFV9000A-450-10K-F | 450 | 355 | 26 | ||
| CFV9000A-500-10K-F | 500 | 400 | 29 | ||
| CFV9000A-560-10K-F | 560 | 450 | 32 | ||
| CFV9000A-630-10K-F | 630 | 500 | 36 | ||
| CFV9000A-700-10K-F | 700 | 560 | 40 | ||
| CFV9000A-790-10K-F | 790 | 630 | 45 | ||
| CFV9000A-890-10K-F | 890 | 710 | 51 | ||
| CFV9000A-1000-10K-F | 1000 | 800 | 58 | ||
| CFV9000A-1125-10K-F | 1125 | 900 | 65 | ||
| CFV9000A-1250-10K-F | 1250 | 1000 | 72 |
Note: The manufacturer reserves the right to modify the product. According to the user's requirements and options, the size and weight will change accordingly. After the manufacturer's product is upgraded, the performance and external dimensions of the product will change without prior notice.
Dimensions

Figure 1 - Suitable for 10KV 2000KW below; 6KV 1120KW below

Figure 2 - Suitable for 10KV 2000KW above; 6KV 1120KW above
Frequently Asked Questions
What is the difference between the 2-quadrant and 4-quadrant CFV9000A models?
The 2-quadrant model supports applied motor power from 200kW up to 12000kW with an overload capacity of 105% continuous, while the 4-quadrant model is designed for 200kW to 2000kW applications featuring higher overload capacities (150% continuous, 180% for 1 minute).
What is the overall efficiency and power factor of the CFV9000A VFD?
The CFV9000A medium-voltage variable frequency drive operates with high efficiency of over 98% at rated output and maintains a power factor of greater than 0.95.
What cooling method and enclosure protection rating does this drive use?
The system utilizes forced air cooling for thermal management and is rated with an IP31 enclosure protection grade, making it suitable for standard indoor installations.
How does the VFD handle high voltage isolation and signal transmission?
High voltage isolation is achieved through electromagnetic coupling combined with multi-channel fiber optic transmission, ensuring safe and reliable control operations.
What protection mechanisms are built into the CFV9000A VFD?
The system features comprehensive protection functions including motor overcurrent, whole machine overvoltage/undervoltage, unit overcurrent/overvoltage/overheating, unit input phase loss, and optical fiber communication failure.
What are the environmental requirements for installing this VFD?
It is designed for indoor installation at altitudes below 1000 meters (customizable for higher altitudes), in environments free of direct sunlight, dust, and corrosive or conductive gases. The operating temperature range is -10℃ to +40℃ with 20% to 90% RH non-condensing humidity.