Basic Parameters
| Model type | CFV9000A 2-quadrant | CFV9000A 4-quadrant | |
| Applied motor power (kW) | 200kW-12000kW | 200kW-2000kW | |
| 4-pole motor is the standard, 6-12-pole motor is selected according to current | |||
| Rated output | Rated power (kW) | 200kW-12000kW | 200kW-2000kW |
| Rated current (A) | Rated current of motor rated voltage | ||
| Overload capacity | 105% continuous, 130% allow 1 minute, 150% allow 3 seconds, 180% immediate protection | 150% continuous, 180% allow 1 minute, 250% immediate protection | |
| Output voltage (kV) | Three-phase: 0-6kV, (0-10kV) | ||
| Waveform | Multiplexed SPWM sine wave | ||
| Input voltage | Phase, Frequency, Voltage | Three phase, 50Hz, 6kV(10kV) | |
| Allowed volatility | Voltage: -10%~+10% Frequency: ±5% -15%~-35% derating for continuous operation |
||
| Basic Performance | Start frequency | 0-10Hz can be set | |
| Accuracy |
Analog setting: less than 0.3% of max frequency setting value (25±10°C) Digital setting: less than 0.1% of max frequency setting value (-10 to +50°C) |
||
| Resolution |
Analog setting: 1/2000 of the maximum frequency setting value Digital setting: 0.01HZ (below 99.99HZ), 0.1HZ (above 100HZ) |
||
| Efficiency | >98%, at rated output | ||
| Power factor | >0.95 | ||
| Control | Acceleration and deceleration time | 0.01~6000.0S, the acceleration and deceleration time can be set separately | |
| Voltage/Frequency Characteristics | Set by the set V/F curve | ||
| PID | Manually set PID parameters | ||
| Auxiliary function | V/F curve, low frequency compensation, rated current, current protection limit setting | ||
| High voltage isolation | Electromagnetic coupling, multi-channel fiber optic transmission | ||
| Control power input | AC 220V 2kVA | ||
| Run | Run operation | Local control (touch screen, cabinet door switch) operation, remote external control operation, upper computer operation (optional) | |
| Given frequency | Touch screen digital given, multi-speed given, external control analog signal (DC4 ~ 20MA) given | ||
| Running status output | Relay status output, inverter fault, alarm, running/stop and other status indication | ||
| Touch screen | Input/output voltage, input/output current, set value, fault status of each unit, running status, transformer status, bus voltage of each unit, etc. | ||
| Protection | Protection function | Motor overcurrent, whole machine overvoltage, whole machine undervoltage, unit overcurrent, unit overvoltage, unit overheating, unit input phase loss, optical fiber communication failure, etc. | |
| Environment | Applicable places | Indoor, no corrosive or conductive gas, dust, direct sunlight, below 1000 meters above sea level (can be customized for high altitude areas) | |
| Ambient temperature/humidity | -10℃~+40℃/20~90%RH without condensation | ||
| Vibration | 5m/s² (below 0.6g) | ||
| Storage temperature | -20 to +65°C (suitable for short-term storage such as transportation) | ||
| Cooling method & protection grade | Forced air cooling/IP31 | ||
Model Specifications
6KV 2-quadrant series (excluding tangent cabinet/connection cabinet)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
| CFV9000A-315-6K-F | 315 | 250 | 30 | 1700*1500*1900 | 1900-2410 |
| CFV9000A-350-6K-F | 350 | 280 | 34 | ||
| CFV9000A-400-6K-F | 400 | 315 | 38 | ||
| CFV9000A-450-6K-F | 450 | 355 | 43 | ||
| CFV9000A-500-6K-F | 500 | 400 | 48 | ||
| CFV9000A-560-6K-F | 560 | 450 | 54 | ||
| CFV9000A-630-6K-F | 630 | 500 | 60 | ||
| CFV9000A-700-6K-F | 700 | 560 | 67 | ||
| CFV9000A-790-6K-F | 790 | 630 | 76 | 2200*1700*2120 | 3250-4000 |
| CFV9000A-890-6K-F | 890 | 710 | 85 | ||
| CFV9000A-1000-6K-F | 1000 | 800 | 96 | ||
| CFV9000A-1125-6K-F | 1125 | 900 | 108 | ||
| CFV9000A-1250-6K-F | 1250 | 1000 | 120 | ||
| CFV9000A-1400-6K-F | 1400 | 1120 | 135 | ||
| CFV9000A-1560-6K-F | 1560 | 1250 | 150 | 3300*1700*2420 | 4950-5600 |
| CFV9000A-1750-6K-F | 1750 | 1400 | 168 | ||
| CFV9000A-2000-6K-F | 2000 | 1600 | 192 | 3600*1700*2420 | 6900-7300 |
| CFV9000A-2250-6K-F | 2250 | 1800 | 217 | ||
| CFV9000A-2500-6K-F | 2500 | 2000 | 241 | ||
| CFV9000A-2800-6K-F | 2800 | 2250 | 270 | ||
| CFV9000A-3125-6K-F | 3125 | 2500 | 301 | ||
| CFV9000A-3500-6K-F | 3500 | 2800 | 337 | ||
| CFV9000A-4100-6K-F | 4100 | 3250 | 390 | 4600*1700*2420 | 11750 |
| CFV9000A-5000-6K-F | 5000 | 4000 | 481 | 5900*1700*2420 | 11800 |
| CFV9000A-6250-6K-F | 6250 | 5000 | 601 | 6500*1700*2620 | 12950-13600 |
10KV 2-quadrant series (excluding tangent cabinet/connection cabinet)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
| CFV9000A-315-6K-T | 315 | 250 | 30 | 2200*1700*2120 | 2400-4430 |
| CFV9000A-350-6K-T | 350 | 280 | 34 | ||
| CFV9000A-400-6K-T | 400 | 315 | 38 | ||
| CFV9000A-450-6K-T | 450 | 355 | 43 | ||
| CFV9000A-500-6K-T | 500 | 400 | 48 | ||
| CFV9000A-560-6K-T | 560 | 450 | 54 | ||
| CFV9000A-630-6K-T | 630 | 500 | 60 | ||
| CFV9000A-700-6K-T | 700 | 560 | 67 | ||
| CFV9000A-790-6K-T | 790 | 630 | 76 | ||
| CFV9000A-890-6K-T | 890 | 710 | 85 | ||
| CFV9000A-1000-6K-T | 1000 | 800 | 96 | ||
| CFV9000A-1125-6K-T | 1125 | 900 | 108 | ||
| CFV9000A-1250-6K-T | 1250 | 1000 | 120 | ||
| CFV9000A-1400-6K-T | 1400 | 1120 | 135 | 3300*1700*2420 | 5520-5600 |
| CFV9000A-1560-6K-T | 1560 | 1250 | 150 | ||
| CFV9000A-1750-6K-T | 1750 | 1400 | 168 | ||
| CFV9000A-2000-6K-T | 2000 | 1600 | 192 | 3600*1700*2420 | 5850-6090 |
| CFV9000A-2250-6K-T | 2250 | 1800 | 217 | ||
| CFV9000A-2500-6K-T | 2500 | 2000 | 241 | ||
| CFV9000A-3125-6K-T | 3125 | 2500 | 301 | 5550*1700*2420 | 10000 |
10KV 4-quadrant series (excluding tangent cabinet/connection cabinet)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
| CFV9000A-315-10K-T | 315 | 250 | 18 | 2800*1700*2120 | 3500-6450 |
| CFV9000A-350-10K-T | 350 | 280 | 20 | ||
| CFV9000A-400-10K-T | 400 | 315 | 23 | ||
| CFV9000A-450-10K-T | 450 | 355 | 26 | ||
| CFV9000A-500-10K-T | 500 | 400 | 29 | ||
| CFV9000A-560-10K-T | 560 | 450 | 32 | ||
| CFV9000A-630-10K-T | 630 | 500 | 36 | ||
| CFV9000A-700-10K-T | 700 | 560 | 40 | ||
| CFV9000A-790-10K-T | 790 | 630 | 45 | ||
| CFV9000A-890-10K-T | 890 | 710 | 51 | ||
| CFV9000A-1000-10K-T | 1000 | 800 | 58 | ||
| CFV9000A-1125-10K-T | 1125 | 900 | 65 | ||
| CFV9000A-1250-10K-T | 1250 | 1000 | 72 | ||
| CFV9000A-1400-10K-T | 1400 | 1120 | 81 | ||
| CFV9000A-1560-10K-T | 1560 | 1250 | 90 | ||
| CFV9000A-1750-10K-T | 1750 | 1400 | 101 | ||
| CFV9000A-2000-10K-T | 2000 | 1600 | 115 | ||
| CFV9000A-2250-10K-T | 2250 | 1800 | 130 | 4100*1700*2420 | 9250-9400 |
| CFV9000A-2500-10K-T | 2500 | 2000 | 144 | ||
| CFV9000A-2800-10K-T | 2800 | 2250 | 162 | ||
| CFV9000A-3125-10K-T | 3125 | 2500 | 180 | ||
| CFV9000A-3500-10K-T | 3500 | 2800 | 202 | 4400*1700*2420 | 9900-9950 |
| CFV9000A-3940-10K-T | 3940 | 3150 | 227 |
6KV All-in-one series (Switch cabinet included)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
| CFV9000A-315-6K-F | 315 | 250 | 30 | 2700*1500*1900 | 1900-2410 |
| CFV9000A-350-6K-F | 350 | 280 | 34 | ||
| CFV9000A-400-6K-F | 400 | 315 | 38 | ||
| CFV9000A-450-6K-F | 450 | 355 | 43 | ||
| CFV9000A-500-6K-F | 500 | 400 | 48 | ||
| CFV9000A-560-6K-F | 560 | 450 | 54 | ||
| CFV9000A-630-6K-F | 630 | 500 | 60 | ||
| CFV9000A-700-6K-F | 700 | 560 | 67 |
10KV All-in-one series (Switch cabinet included)
| Specifications | Rated Capacity (kVA) | Adapted motor rated power (kW) | Adapted motor rated current (A) | Overall dimensions (W*D*H) | Weight (kG) |
| CFV9000A-315-10K-F | 315 | 250 | 18 | 2700*1500*1900 | 2160-3100 |
| CFV9000A-350-10K-F | 350 | 280 | 20 | ||
| CFV9000A-400-10K-F | 400 | 315 | 23 | ||
| CFV9000A-450-10K-F | 450 | 355 | 26 | ||
| CFV9000A-500-10K-F | 500 | 400 | 29 | ||
| CFV9000A-560-10K-F | 560 | 450 | 32 | ||
| CFV9000A-630-10K-F | 630 | 500 | 36 | ||
| CFV9000A-700-10K-F | 700 | 560 | 40 | ||
| CFV9000A-790-10K-F | 790 | 630 | 45 | ||
| CFV9000A-890-10K-F | 890 | 710 | 51 | ||
| CFV9000A-1000-10K-F | 1000 | 800 | 96 | ||
| CFV9000A-1125-10K-F | 1125 | 900 | 108 | ||
| CFV9000A-1250-10K-F | 1250 | 1000 | 120 |
Note: The manufacturer reserves the right to modify the product. According to the user's requirements and options, the size and weight will change accordingly. After the manufacturer's product is upgraded, the performance and external dimensions of the product will change without prior notice.
Dimensions

Figure 1 - Suitable for 10KV 2000KW below; 6KV 1120KW below

Figure 2 - Suitable for 10KV 2000KW above; 6KV 1120KW above
Frequently Asked Questions
What is the overload capacity of the CFV9000A series?
For the 2-quadrant model, the overload capacity is 105% continuous, 130% allowed for 1 minute, 150% allowed for 3 seconds, and immediate protection at 180%. For the 4-quadrant model, it is 150% continuous, 180% allowed for 1 minute, and immediate protection at 250%.
What are the input voltage requirements and allowed volatility?
The system requires a three-phase input at 50Hz, with a rated voltage of 6kV (or 10kV). The allowed voltage volatility is -10% to +10%, and frequency volatility is ±5%. Continuous operation is supported with derating between -15% and -35%.
What efficiency and power factor ratings does this drive offer?
The CFV9000A achieves an efficiency of over 98% at rated output and maintains a power factor of greater than 0.95.
How is high voltage isolation achieved in the system?
High voltage isolation is managed safely through electromagnetic coupling and multi-channel fiber optic transmission.
What are the environmental requirements for standard installation?
It is designed for indoor installation without corrosive or conductive gas, dust, or direct sunlight. The standard operating altitude is below 1000 meters (customizable for higher altitudes), with an ambient temperature range of -10℃ to +40℃ and 20% to 90% RH non-condensing humidity.
What cooling method and protection rating are applied?
The CFV9000A series uses forced air cooling and features an IP31 enclosure protection grade.