Availability: | |
---|---|
1. Comprehensive compensation
It can realize the three functions of harmonic control, reactive power compensation and three-phase unbalanced current regulation, and comprehensively compensate for power quality problems.
At the same time, the three functions can be combined and prioritized according to the load environment and needs.
2. Wide filtering range and fast response
2-50 harmonics can be compensated at the same time, or a specific harmonic can be selected for compensation, and the total current distortion rate after compensation is less than 5%.
The harmonic current detection algorithm adopts the efficient TTA algorithm, which is fast and accurate, and truly achieves a full response of 10ms.
3. High-end quality of core components
German original IGBT module, three-level topology.
American TIDSP control chip and ALTERA and CYCLONE 3 series FPGA chips constitute a powerful three-core control system.
TI's double-ended high-speed input 12-bit A/D data conversion chip makes signal sampling more accurate and reliable.
4. Efficient heat dissipation
The structural design of layered heat dissipation makes the air duct independent, better heat dissipation performance, and effectively isolates dust and other pollutants.
5. Independent fan, detachable
The fan can be disassembled and assembled independently, which is easy and convenient to replace and enhances the reliability of heat dissipation.
6. Modular design
Various capacity modules can be combined arbitrarily to improve the reliability and maintainability of the whole machine.
7. Human-Machine Interface
It adopts a high-resolution 5-inch LCD liquid crystal display touch screen to measure various operating data of the product in real time and change the control parameters online. The operation is simple and can be controlled remotely through the mobile phone APP.
Active harmonic filters can be widely used in distribution networks of industry, commerce and institutional groups. Such as: power systems, electrolytic plating enterprises, water treatment equipment, petrochemical enterprises, large shopping malls and office buildings, precision electronics enterprises, power supply systems of airports/ports, medical institutions, etc.
These places contain a large number of nonlinear loads, and harmonics are generated by nonlinear loads.
Common typical nonlinear loads are:
1. Soft starter (SCR motor starter);
2. Switching power supply, UPS, inverter components, battery chargers;
3. Frequency converter;
4. Electronic data image equipment-such as radio transmission equipment such as TV, controllable lighting equipment;
5. Rectifiers, fluorescent lamps, etc.
Economic Benefits of Harmonic Control
1. Energy saving 5%~8%
2. Reduce capacity, reduce investment in transformers, circuit breakers and cables
3. Improve productivity and maintain continuous power supply
Solution 1: Centralized compensation
Centralized management of transformers, compensation of harmonic currents and reactive currents on the public bus, to ensure safe operation of the upper-level network.
Suitable for occasions:
Where the number of nonlinear loads is large and the power of individual loads is small.
Solution 2: branch compensation
Filtering is performed on the branch circuit with large harmonic content in the power grid to ensure that the harmonic current of the branch circuit does not flow into the common bus.
Suitable for occasions:
Where nonlinear loads are concentrated in the same branch circuit.
Solution 3: In situ compensation
Local compensation is performed for the load to ensure that the harmonic current does not interfere with other equipment.
Applicable to:
Large capacity nonlinear load.
Product Series | XPQ-EA-4L |
Power supply voltage | 400V (±20%) |
690V (±20%) | |
Single unit's Filter Capability (A) | 30 |
50 | |
75 | |
100 | |
150 | |
Phase / Wiring | 3 phase 4 Wiring |
Working Frequency | 50 (±20%) |
Number of Filtering harmonic wave | 2 ~ 50 times (All or selected harmonic frequency can be eliminated) |
Neutral filter capability | Three times the effective value of the phase current |
Filtering capability | >97% |
CT demand | Three current transformers with precision above 0.5 grade and secondary current 5A |
Compensation method | 5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00 |
Instantaneous response time | Add, minus and confirm |
Full responce time | Fast upload and download parameters |
IGBT switch frequency | Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions |
Module extension capability | Up to 10 functional modules can be extended |
Protection function | Overcurrent, grid voltage, undervoltage, overheating, busbar overvoltage, short circuit, fan failure, power failure and current limiting protection, etc. |
Interface display information | 1. Voltage and current of each phase, power factor, THD and other parameters 2. Grid, load current waveform, three-phase voltage waveform 3. Three-phase IGBT temperature display 4. Operation mode setting, parameter setting |
Overload protection | Set current limiting capability with parameters |
Communication | WIFI, RS232, RS485 |
Cooling method | Forced cooling |
Degree of protection | IP20,higher protection class can be customized |
Color | Matt black, other colors are available upon request |
Installation Environment | Temperature:-10℃ ~ +45℃ Humidity: max 95% RH (no condensation) |
Altitude | It is recommended that the altitude of installation should not exceed 1000 meters, and it should be derated for use at higher altitude. |
Equipment size (W*D*H) mm | Module: 484*640*200 (drawer type) 440*212*649(wall-mounted) Whole cabinet:800*800*2200 |
Module reset | 34kg (100A) 47kg (150A) |
Scope of application | Applicable to power grid system with neutral line, it can filter out harmonics of phase line and neutral line at the same time, and compensate reactive power |
Designation (i.e. XPQ-EA-4L-050-04-RL) | Description |
XPQ | Xichi product code |
EA | Enhanced Active Power Filter |
4L | 4L: 3phase 4wiring system; 3L: 3phase 3wiring system; |
050 | 150: Filtering current is 150A; 100: Filtering current is 100A; 075: Filtering current is 75A; 050: Filtering current is 50A; 030: Filtering current is 30A; |
04 | Voltage Class 04: 400V 06: 690V |
RL | Installation method RL: Drawer type with screen RN: Drawer type without screen HL: wall-mounted with screen HN: Wall-mounted without screen |
Drawer Type
XPQ-EA-4L | W | H | D | w | h | d | Fixing screws | Net Weight |
30A | 484 | 200 | 640 | 465 | 158 | 610 | M6 | 34kg |
50A | ||||||||
75A | ||||||||
100A | ||||||||
150A | 544 | 250 | 646 | 525 | 180 | 610 | 47kg |
Wall-mounted Type
XPQ-EA-4L | W | H | D | w | h | d | Fixing screws | Net Weight |
30A | 440 | 657 | 212 | 375 | 633 | / | M8 | 35kg |
50A | ||||||||
75A | ||||||||
100A | ||||||||
150A | 500 | 657 | 262 | 375 | 633 | / | 48kg |
1. Comprehensive compensation
It can realize the three functions of harmonic control, reactive power compensation and three-phase unbalanced current regulation, and comprehensively compensate for power quality problems.
At the same time, the three functions can be combined and prioritized according to the load environment and needs.
2. Wide filtering range and fast response
2-50 harmonics can be compensated at the same time, or a specific harmonic can be selected for compensation, and the total current distortion rate after compensation is less than 5%.
The harmonic current detection algorithm adopts the efficient TTA algorithm, which is fast and accurate, and truly achieves a full response of 10ms.
3. High-end quality of core components
German original IGBT module, three-level topology.
American TIDSP control chip and ALTERA and CYCLONE 3 series FPGA chips constitute a powerful three-core control system.
TI's double-ended high-speed input 12-bit A/D data conversion chip makes signal sampling more accurate and reliable.
4. Efficient heat dissipation
The structural design of layered heat dissipation makes the air duct independent, better heat dissipation performance, and effectively isolates dust and other pollutants.
5. Independent fan, detachable
The fan can be disassembled and assembled independently, which is easy and convenient to replace and enhances the reliability of heat dissipation.
6. Modular design
Various capacity modules can be combined arbitrarily to improve the reliability and maintainability of the whole machine.
7. Human-Machine Interface
It adopts a high-resolution 5-inch LCD liquid crystal display touch screen to measure various operating data of the product in real time and change the control parameters online. The operation is simple and can be controlled remotely through the mobile phone APP.
Active harmonic filters can be widely used in distribution networks of industry, commerce and institutional groups. Such as: power systems, electrolytic plating enterprises, water treatment equipment, petrochemical enterprises, large shopping malls and office buildings, precision electronics enterprises, power supply systems of airports/ports, medical institutions, etc.
These places contain a large number of nonlinear loads, and harmonics are generated by nonlinear loads.
Common typical nonlinear loads are:
1. Soft starter (SCR motor starter);
2. Switching power supply, UPS, inverter components, battery chargers;
3. Frequency converter;
4. Electronic data image equipment-such as radio transmission equipment such as TV, controllable lighting equipment;
5. Rectifiers, fluorescent lamps, etc.
Economic Benefits of Harmonic Control
1. Energy saving 5%~8%
2. Reduce capacity, reduce investment in transformers, circuit breakers and cables
3. Improve productivity and maintain continuous power supply
Solution 1: Centralized compensation
Centralized management of transformers, compensation of harmonic currents and reactive currents on the public bus, to ensure safe operation of the upper-level network.
Suitable for occasions:
Where the number of nonlinear loads is large and the power of individual loads is small.
Solution 2: branch compensation
Filtering is performed on the branch circuit with large harmonic content in the power grid to ensure that the harmonic current of the branch circuit does not flow into the common bus.
Suitable for occasions:
Where nonlinear loads are concentrated in the same branch circuit.
Solution 3: In situ compensation
Local compensation is performed for the load to ensure that the harmonic current does not interfere with other equipment.
Applicable to:
Large capacity nonlinear load.
Product Series | XPQ-EA-4L |
Power supply voltage | 400V (±20%) |
690V (±20%) | |
Single unit's Filter Capability (A) | 30 |
50 | |
75 | |
100 | |
150 | |
Phase / Wiring | 3 phase 4 Wiring |
Working Frequency | 50 (±20%) |
Number of Filtering harmonic wave | 2 ~ 50 times (All or selected harmonic frequency can be eliminated) |
Neutral filter capability | Three times the effective value of the phase current |
Filtering capability | >97% |
CT demand | Three current transformers with precision above 0.5 grade and secondary current 5A |
Compensation method | 5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00 |
Instantaneous response time | Add, minus and confirm |
Full responce time | Fast upload and download parameters |
IGBT switch frequency | Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions |
Module extension capability | Up to 10 functional modules can be extended |
Protection function | Overcurrent, grid voltage, undervoltage, overheating, busbar overvoltage, short circuit, fan failure, power failure and current limiting protection, etc. |
Interface display information | 1. Voltage and current of each phase, power factor, THD and other parameters 2. Grid, load current waveform, three-phase voltage waveform 3. Three-phase IGBT temperature display 4. Operation mode setting, parameter setting |
Overload protection | Set current limiting capability with parameters |
Communication | WIFI, RS232, RS485 |
Cooling method | Forced cooling |
Degree of protection | IP20,higher protection class can be customized |
Color | Matt black, other colors are available upon request |
Installation Environment | Temperature:-10℃ ~ +45℃ Humidity: max 95% RH (no condensation) |
Altitude | It is recommended that the altitude of installation should not exceed 1000 meters, and it should be derated for use at higher altitude. |
Equipment size (W*D*H) mm | Module: 484*640*200 (drawer type) 440*212*649(wall-mounted) Whole cabinet:800*800*2200 |
Module reset | 34kg (100A) 47kg (150A) |
Scope of application | Applicable to power grid system with neutral line, it can filter out harmonics of phase line and neutral line at the same time, and compensate reactive power |
Designation (i.e. XPQ-EA-4L-050-04-RL) | Description |
XPQ | Xichi product code |
EA | Enhanced Active Power Filter |
4L | 4L: 3phase 4wiring system; 3L: 3phase 3wiring system; |
050 | 150: Filtering current is 150A; 100: Filtering current is 100A; 075: Filtering current is 75A; 050: Filtering current is 50A; 030: Filtering current is 30A; |
04 | Voltage Class 04: 400V 06: 690V |
RL | Installation method RL: Drawer type with screen RN: Drawer type without screen HL: wall-mounted with screen HN: Wall-mounted without screen |
Drawer Type
XPQ-EA-4L | W | H | D | w | h | d | Fixing screws | Net Weight |
30A | 484 | 200 | 640 | 465 | 158 | 610 | M6 | 34kg |
50A | ||||||||
75A | ||||||||
100A | ||||||||
150A | 544 | 250 | 646 | 525 | 180 | 610 | 47kg |
Wall-mounted Type
XPQ-EA-4L | W | H | D | w | h | d | Fixing screws | Net Weight |
30A | 440 | 657 | 212 | 375 | 633 | / | M8 | 35kg |
50A | ||||||||
75A | ||||||||
100A | ||||||||
150A | 500 | 657 | 262 | 375 | 633 | / | 48kg |
CMC-MX soft starter is suitable for starting and protecting general squirrel-cage AC asynchronous motors. Adapted motor power from 7.5kW to 280kW. It can smoothly start/stop the motor without steps, avoid mechanical and electrical shocks caused by traditional methods such as direct start, star/delta start, auto-coupling step-down start, etc.
XiChi XPQ Active Filters are used for Harmonic Reduction in Haier IOT Center. The active power harmonic filter (APF/AHF) suppresses the harmonic current on the load side to a great extent, and the overall harmonic filtering effect is obvious.
In the process of starting the motor, the soft starter gradually changes the conduction angle of the thyristor, so that the starting current of the motor rises smoothly from zero to the maximum value. The whole process runs smoothly, the reliability of the motor power supply is high, the impact torque on the mechanical load is reduced, the impact on the motor itself is small, and the service life of the motor and the entire equipment is prolonged.
The harmonic control technology of active filter equipment is one of the effective means to improve the quality of power supply. After the popularization and application of APF in the power supply system of hospital buildings, the generated harmonics can be controlled within the minimum range. Realize scientific and rational use of electricity, restrain grid pollution, improve power quality, ensure the safety of medical equipment, and bring huge economic and social benefits to users.
Project requirementsHigh voltage soft start device10KV 280kw * 8 units400kw * 6 unitsHigh voltage SVG1 unit
The use of high-voltage motor soft-start device can effectively improve the service life of the pump and the reliability of power supply. CMV series of products are widely used in electric power, building materials, chemical industry, metallurgy steel, paper making and other industries with rated voltage of 3000-10000V. It can be used well with various electromechanical equipment such as water pump, fan, compressor, pulverizer, mixer, belt conveyor, etc. It is an ideal high-voltage motor starting and protection equipment.
The VFD has achieved remarkable power-saving effect when used in the drive control of fans and pumps. It is an ideal speed control method. It not only improves the equipment efficiency, but also meets the production process requirements, and greatly reduces the equipment maintenance and repair costs, and also reduces the shutdown period.
Using VFD for speed regulation, it is convenient to realize multi-stage speed regulation of mining winches, and improve system stability and safety. It reduces operation failures and downtime, saves manpower and material resources, improves coal transportation capacity, and also has considerable indirect economic benefits.
APF is a new type of power electronic device for dynamically suppressing harmonics and compensating reactive power. It can quickly track and compensate harmonics of different sizes and frequencies. Compared with the passive filter device, the active filter device has better treatment effect, and it can mainly filter out multiple and high-order harmonics at the same time without causing resonance.
CFV9000A series high-voltage variable frequency speed regulation system, with high-speed DSP as the control core, adopts space voltage vector control technology and cell-series multi-level technology, with high reliability, easy operation and high performance as the design goals, to meet the needs of users for various load adjustments.
APF can not only compensate various harmonics, but also suppress flicker and compensate reactive power; the filtering characteristics are not affected by system impedance, etc., which can eliminate the risk of resonance with system impedance; it has an adaptive function, which can automatically track and compensate for changing Harmonics, that is, have the characteristics of high controllability and fast response.
XFC500 variable frequency drive is used in amusement ride to realize functions such as speed regulation, energy saving, and protection of mechanical equipment. With small size, light weight, large torque, high precision, strong function, high reliability, simple operation, easy communication and other functions.
The soft starter integrates motor soft start, soft stop and multi-function protection. In the heating industry, soft starters can be used in various applications of squirrel-cage asynchronous motors that do not require speed regulation, especially suitable for various pump loads or fan loads that require soft start and soft stop.
Application of CMV HV soft starter in piston pump in petrochemical industry.
Project Overview:The 1850 water pump house of Yaojie Coal and Electricity Group used oil circuit breaker to control high-voltage electricity, and reactor was used for starting, with large starting current and little protection function.
OverviewProduct model: CMV-800-10Load type: Crushing machinePhoto
Project infoLoad type: induced draft fanRated voltage: 10KVMotor rated current: 54ANumber of motor poles: 6 polesHigh voltage soft start model: CMV-900-10On-site parameter setting:Starting voltage: 65%Current limit multiple: 4 timesStartup time: 20Project infoLoad type: induced draft fanRated voltag
Frequency inverter applied to glass tempering furnace advantages: Low frequency and stable operation during standby, saving energy; The starting current is small, the impact on the power grid and machinery is small, and the service life of the equipment is prolonged; Quick start, shorten the production process and improve production efficiency; Control the frequency required for fast response, and control to meet the production process requirements.
The application of frequency inverters to plastic extruders has the advantages of reducing production energy consumption, improving productivity and product quality, and reducing the impact on the power grid during startup. The main extruder is composed of extrusion system, transmission system and heating and cooling system. The transmission part usually consists of a motor, a reduction box and a bearing.