XST260 Smart Low-voltage Soft Starter, 220/380/480V
Appearance
-
A
Terminals are on the top of the device, clearly marked, easy and quick to install, and
convenient for wiring
B
3.5-inch large display screen and status indicator screen, dual-screen display
C
Plastic panels improve the safety of the entire machine
D
Detachable keypad can be installed on the control cabinet door
E
Clear status indication and alarm identification; quickly identify device status
Basic Parameters
Control voltage AC110V - 220V ±15%, 50/60Hz Mains Voltage AC220V, AC380V, AC480V ± 10% Nominal current 18A~780A, 20 rated values in total Applicable motor Squirrel cage AC asynchronous motor Start methods Voltage ramp start, Current ramp start, Pump start control, Direct start, Kickstart Stop methods Voltage ramp, Soft stop, Brake, Free stop, Pump stop Logical input Impedance 1.8 KΩ, Mains voltage +24V Start frequency No more than 10 times per hour (recommended) IP ≤55kW, IP00 ≥75kW, IP20 Cooling type ≤55kW, Natural cooling ≥75kW, Forced air cooling Installation type Wall mounted Communication method RS485 (Optional) Environmental condition When sea altitude is above 2,000m, soft starter should be derated for use. Ambient temperature: -10 ~ +40°C Relative humidity: less than 95% (20°C±5°C) Free of flammable, explosive and corrosive gas or conductive dust. Indoor installation, good ventilation, vibration less than 0.5G
Features
-
● Communication expansion cardProfibus communication expansion card can be built-in.● External keypad + extra large screen availableEasily removable keypad for remote operation.● Motor preheatingIn low-temperature environments, the motor is heated before operation without the need for external heating equipment.● More comprehensive motor protection functionsOvervoltage protection, undervoltage protection, overcurrent protection, overload protection, stall protection, bypass fault, thyristor fault, three-phase current imbalance, motor overheating protection, etc.● Pump control functionUnique start and stop control for pump loads. The pump starting function reduces the starting current of pump loads; the pump stopping function reduces the water hammer effect.● Pump cleaning functionSelf-service cleaning of siltation in the pump to prevent overflow, overload and other failures caused by blocked rotor.● Fan braking functionDynamic braking can quickly stop the running load; static braking can bring the running load to a stop state under the action of external force.● Low speed operation functionIt has the functions of low-speed forward rotation and low-speed reverse rotation, and can adjust the load running direction at low speed before the motor starts normally.● Wide supply voltage range220V-500V main power input voltage.
Model specifications
-
Applicable motor power
(kW)
Model No.
Rated current
(A)
Motor rated current (A)
Size of primary wires
(copper wire)
standard wiring
Inside delta connection
7.5
XST260-0018-03
18
18
32
4 mm2
11
XST260-0024-03
24
24
42
6 mm2
15
XST260-0030-03
30
30
52
10 mm2
18.5
XST260-0039-03
39
39
68
10 mm2
22
XST260-0045-03
45
45
78
16 mm2
30
XST260-0060-03
60
60
104
25 mm2
37
XST260-0076-03
76
76
132
35 mm2
45
XST260-0090-03
90
90
156
35 mm2
55
XST260-0110-03
110
110
190
35 mm2
75
XST260-0150-03
150
150
260
50 mm2
90
XST260-0180-03
180
180
312
30×4 copper bar
110
XST260-0218-03
218
218
378
30×4 copper bar
132
XST260-0260-03
260
260
450
30×4 copper bar
160
XST260-0320-03
320
320
554
30×4 copper bar
185
XST260-0370-03
370
370
640
40×5 copper bar
220
XST260-0440-03
440
440
762
40×5 copper bar
250
XST260-0500-03
500
500
866
40×5 copper bar
280
XST260-0560-03
560
560
969
40×5 copper bar
315
XST260-0630-03
630
630
1090
50×8 copper bar
400
XST260-0780-03
780
780
1350
50×8 copper bar
Standard wiring refers to the delta or star connection of the motor windings, and the thyristor of the soft starter is connected between the power supply and the motor.Inner delta connection refers to the delta connection of the motor windings, and the thyristor is directly connected in series with the motor winding.
Drawings
-
Power range/kW
G
H
I
K
L
M
D
E
F
A/B/C
Net weight/kg
7.5 ~ 30
160
275
189
140
263
5.5
92
66
66
50
5.2
37 ~ 55
5.7
75 ~ 160
285
450
295
240
386
9
174
178
144
50
23.3
185 ~ 280
320
520
320
250
446
9
197
189
146
50
33.6
315 ~ 400
490
744
344
400
620
11
306
220
162
50
64.2
- 7.5kW ~ 55kW
- 75kW ~ 160kW
- 185kW ~ 280kW
- 315kW ~ 400kW
-
Applications
-
Belt conveyor
When material jam occurs, the low-speed forward and reverse functions can be used as appropriate to allow the belt conveyor to drive the jammed material back and forth to alleviate system jams.
Fan
Application of dynamic braking function:
Dynamic braking can be used to quickly stop large inertia loads and solve the problem of long shutdown time of large inertia fans.
Application of static braking function:
When the fan rotates due to external wind force, the static braking function can stop the fan first so that it can be started later.
Comprehensive moisture-proof and anti-corrosion solution
Water pump
Unique pump control features:
Why is the pump control feature needed?
Pump systems are susceptible to fluid shock and surge during motor starting and stopping.
The pump control function can effectively control the load current when the pump starts and stops, extending the pump life.
When starting:
In pump starting mode, the output voltage increases according to the pump load characteristic curve until the output voltage reaches full voltage.
When stopping:
The pump stop curve can effectively slow down the water hammer phenomenon caused by the pump load when it stops.
Application scenarios for pump cleaning:
When the blades are blocked by mud, the starting current of the water pump will be too large, resulting in overcurrent or overload protection. After using the pump cleaning function, the impeller is self-cleaned before the water pump is started to ensure normal pumping.